User Manual

4
The device must only be installed, connected and put into operation by a qualified
electrician as the safe function of the device and machinery is only guaranteed
when installation is correctly carried out.
Disconnect the unit externally before handling it.
In case of malfunction of the device or uncertainties please contact the
manufacturer. Tampering with the device can seriously affect the safety of
operators and machinery. This is not permitted and leads to an exclusion of liability
and warranty.
2.2 Radio equipment
In general, radio equipment must not be used in the vicinity of petrol stations, fuel
depots, chemical plants or blasting operations.
Do not transport and store any flammable gases, liquids or explosive
substances near the unit.
2.3 Interference of electronic and medical devices
Operation can affect the function of electronic devices that are not correctly
shielded.
Disconnect the device in the vicinity of medical equipment.
Contact the manufacturer of the corresponding device in case of any
interference.
3 Functions and features
The device is suited for non-contact reading and writing of system-compliant RFID
tags (ID tags).
Data transmission is done via the CAN bus.
4 Functions
4.1 Operating principle
The ID tags are operated passively, i.e. without battery. The energy required for
operation is supplied by the read/write head.The physical principle of the energy
transfer is based on inductive coupling. The integrated antenna coil in the read/
write head generates a magnetic field which partly penetrates the antenna coil of
the ID tag. A voltage is generated by induction that supplies the data carrier with
energy.