User's Manual

26
[Vehicle identification (barrier)]
Application for detecting and describing individual tags in the antenna field, which are not moving� The
distance between the tags and the antenna should be less than a few metres�
[Shelf application]
Application for detecting and describing very many tags in the antenna field, which are not moving�
The distance between the tags and the antenna should be less than 1 m�
[People identification]
Application for detecting multiple tags in the antenna field, which are moving at not more than 3 m/s�
The distance between the tags and the antenna should be less than 1 m
If there are more applications than fit on the screen, the buttons alongside the applications are activated
to allow scrolling�
When "max� read frequency" is selected, for every detection (inventory) all tags are reset in order to read
them afresh� Under some circumstances the time allowed for detecting the tags may be insufficient, so
that some transponders are not detected� The frequency for detecting the tags should then be increased�
When "max� read reliability" is selected, tags that have already been read are not reset at every detection
(inventory), provided they are still being supplied with power� This means that only those tags which have
not yet been registered are detected� The certainty that all tags are read is thus increased�
Clicking on the [Apply settings] button saves the settings that were made, as well as the settings for the
selected application, in the selected parameter set� This is done by first resetting them to the factory set-
tings and thus overwriting the previous configuration� This must be acknowledged� Success is indicated
by the [Apply settings] button glowing briefly, and by display of a success message in the status window
If the process fails, the button glows briefly orange for a warning or briefly red for an error and by display
of a warning description or error description in the status window� �If the failure was due to an entry being
omitted, in addition the field that is lacking the entry glows red�
If the settings have been loaded successfully, a switch can now be made to the [Basic read functions] tab
and the read process can be started�