5.3 Avoiding interference
The device generates a modulated electrical field with a frequency of 125 kHz.
To avoid interference of the data communication no other devices generating
interference emission in this frequency band must be operated in its vicinity. Such
devices are for example frequency converters and switched-mode power supplies.
5.4 Mechanical design
On delivery the sensing face is facing the front.
2
1
1: Antenna head (can be aligned)
2: Fixing element
Factory setting
5.5 Alignment of the sensing face
180° 90°
1. Loosen the screw. 2. Remove the antenna head from the fixing
element and turn it.
3. Attach the fixing element to the antenna
head.