Operating Instructions
Table Of Contents
- Contents
- 1 Preliminary note
- 2 Safety instructions
- 3 Intended use
- 4 Items supplied
- 5 Function
- 5.1 Device overview
- 5.2 IO-Link
- 5.2.1 General information
- 5.2.2 Device-specific information
- 5.2.3 Device-specific parameters
- 5.2.3.1 Parameter “Data Hold Time”
- 5.2.3.2 Parameter "Auto-Read/Write Address"
- 5.2.3.3 Parameter "Auto-Read/WriteData Length"
- 5.2.3.4 Parameter "ID Tag Memory Area for Auto-Read/Write"
- 5.2.3.5 Parameter “ID Tag Access Password"
- 5.2.3.6 Parameter "ID Tag Selection Target
- 5.2.3.7 Parameter "ID Tag Selection Mask”
- 5.2.3.8 Parameter "ID Tag Selection Start Bit”
- 5.2.3.9 Parameter "ID Tag Selection Length”
- 5.2.3.10 Parameter "RSSI Filter Lowest Value”
- 5.2.3.11 Parameter "RSSI Filter Highest Value”
- 5.2.3.12 Parameter "Activate RSSI Filter”
- 5.2.3.13 Parameter “Antenna Output Power for Read Access"
- 5.2.3.14 Parameter “Antenna Output Power for Write Access"
- 5.2.3.15 Parameter "ID Tag Detection Mode”
- 5.3 ID tag
- 6 Mounting
- 7 Electrical connection
- 8 Operating and display elements
- 9 Operation
- 9.1 Status bits
- 9.2 Operating mode "SINGLE EPC
- 9.3 Operating Mode “READ DATA AUTO"
- 9.4 Operating Mode “WRITE DATA AUTO"
- 9.5 Operating mode "EPC REPORT
- 9.6 Operating mode "EPC LIST
- 9.7 Operating mode "WRITE EPC”
- 9.8 Operating mode "READ DATA
- 9.9 Operating mode "WRITE DATA”
- 9.10 Operating mode "LOCK DATA”
- 9.11 Error values when executing commands
- 10 Maintenance, repair and disposal
- 11 Approvals / standards
- Glossary
DTI801 DTI901 DTI911 DTI961
42
Error value Name Description
0x41 UHF_COMMAND_ERROR_NO_RE-
SPONSE
IT tag does not respond. ID tag out of range or operation
not supported by ID tag.
0x42 UHF_COMMAND_ERROR_RX_ERROR Error receiving the ID tag response.
0x43 UHF_COMMAND_ER-
ROR_INT_MODE_CHANGE
Internal error: command mode cannot be changed.
0x51 UHF_SYNTAX_ERROR Command parameter incorrect.
0x61 UHF_ERROR_GEN2_TAG_OTHER_ER-
ROR
Command is not supported by the ID tag.
0x62 UHF_ERROR_GEN2_TAG_MEMO-
RY_OVERRUN
The specified data range is outside the available data
range.
0x63 UHF_ERROR_GEN2_TAG_MEMO-
RY_LOCKED
The specified data range is already locked.
0x64 UHF_ERROR_GEN2_TAG_INSUFFI-
CIENT_POWER
The power supply of the ID tag is insufficient.
0x65 UHF_ERROR_GEN2_TAG_NON_SPECIF-
IC_ERROR
Not further specified error of the ID tag.
0x66 UHF_ERROR_READ_WRITE_TIMEOUT Read/write operation timeout.
0x67 UHF_ERROR_INTERNAL_PROCESSING Internal data processing error.
0x71 UHF_ERROR_MAC_GENERAL The device's "UHF Frontend" module reports general er-
rors.
0x72 UHF_ERROR_MAC_CRC_MISMATCH The device's "UHF Frontend" module reports checksum er-
rors.
0x73 UHF_ERROR_MAC_NO_TAG_RE-
SPONSE
The device's "UHF Frontend" module fails to report a re-
sponse from the ID tag.
0x74 UHF_ERROR_MAC_TAG_LOST The device's "UHF Frontend" module has lost connection to
the ID tag.