User manual 2bright Pint TW200 IP LED PAR
Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 Internet: www.thomann.de 24.03.
Table of contents Table of contents 1 General information................................................................................................................................. 1.1 Further information........................................................................................................................... 1.2 Notational conventions.................................................................................................................... 1.3 Symbols and signal words.....
Table of contents 7.6 7.7 7.8 7.9 7.10 7.11 4 2bright Pint TW200 IP LED PAR Functions in 2-channel DMX mode, variant B....................................................................... Functions in 3-channel DMX mode........................................................................................... Functions in 5-channel DMX mode, variant A....................................................................... Functions in 5-channel DMX mode, variant B.......................................
2bright Pint TW200 IP LED PAR 5
General information 1 General information This user manual contains important information on the safe operation of the device. Read and follow all safety notes and all instructions. Save this manual for future reference. Make sure that it is available to all persons using this device. If you sell the device to another user, be sure that they also receive this manual. Our products and user manuals are subject to a process of continuous development.
General information 1.1 Further information On our website (www.thomann.de) you will find lots of further information and details on the following points: Download This manual is also available as PDF file for you to download. Keyword search Use the search function in the electronic version to find the topics of interest for you quickly. Online guides Our online guides provide detailed information on technical basics and terms.
General information 1.2 Notational conventions This manual uses the following notational conventions: Letterings The letterings for connectors and controls are marked by square brackets and italics. Examples: [VOLUME] control, [Mono] button. Displays Texts and values displayed on the device are marked by quotation marks and italics. Examples: ‘24ch’ , ‘OFF’ . Text input Text inputs that are carried out on the device are indicated by typewriter font.
General information Instructions The individual steps of an instruction are numbered consecutively. The result of a step is indented and highlighted by an arrow. Example: 1. Switch on the device. 2. Press [Auto]. ð Automatic operation is started. 3. Switch off the device. 1.3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual.
General information Signal word Meaning DANGER! This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided. WARNING! This combination of symbol and signal word indicates a pos‐ sible dangerous situation that can result in death or serious injury if it is not avoided.
General information Warning signs Type of danger Warning – dangerous optical radiation. Warning – suspended load. Warning – danger zone.
Safety instructions 2 Safety instructions Intended use This device is intended for use as an electronic lighting effect by means of LED technology. The device is designed for professional use only and is not suitable for use in households. Use the device only as described in this user manual. Any other use or use under other operating con‐ ditions is considered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use.
Safety instructions Safety DANGER! Danger for children Ensure that plastic bags, packaging, etc. are disposed of properly and are not within reach of babies and young children. Choking hazard! Ensure that children do not detach any small parts (e.g. knobs or the like) from the unit. They could swallow the pieces and choke! Never let children unattended use electrical devices. DANGER! Electric shock caused by short-circuit Always use proper ready-made insulated mains cabling (power cord).
Safety instructions WARNING! Risk of epileptic shock Strobe lighting can trigger seizures in photosensitive epilepsy. Sensitive persons should avoid looking at strobe lights. WARNING! Risk of burns The surface of the device can become very hot during operation. Do not touch the device with bare hands during operation, and after switching off wait for at least 15 minutes.
Safety instructions NOTICE! Risk of fire and overheating The use with closed barn doors can cause fire or overheating in the spotlight. The lifetime of the LEDs will be reduced when using the device with closed barn doors. Otherwise, the integrated thermostat causes a thermically reasonable shutdown. Use the device only with open barn doors.
Features 3 Features The device is suitable as a blinder, strobe and floodlight for stages and all kinds of events. Special features of the device: n n n n n n n n n n 16 2bright Pint TW200 IP LED PAR 1 × 3in1 WW/CW/A COB LED (200 watt) Adjustable colour temperature of 2700 to 5800 K Control via DMX, RDM and via buttons and display on the unit Blinder channel for halogen effect Intense pulse and strobe effects Selectable dimmer curves and dimmer speeds Adjustable LED repetition rates from 900 to 10.
Features Information about protection class IP65 Equipment with protection class IP65 are dust-tight and completely protected against contact (first code number). They are also protected against splash water from any angle (second code digit). That is why this equipment can also be used outdoors. Event technology equipment is generally only designed for temporary use however (event lighting) and not for permanent use outdoors.
Installation 4 Installation Unpack and check carefully there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the product against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage, respectively. WARNING! Risk of injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country.
Installation NOTICE! Risk of overheating Always ensure sufficient ventilation. The ambient temperature must not exceed the limits stated in the chapter Tech‐ nical Specifications of the User Manual. NOTICE! Use of stands When mounting the device onto a stand, ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand.
Installation NOTICE! Possible data transmission errors For error-free operation make use of dedicated DMX cables and do not use ordi‐ nary microphone cables. Never connect the DMX input or output to audio devices such as mixers or ampli‐ fiers. NOTICE! Possible damage due to moisture Moisture entering into open connectors (plugs and couplers) of DMX or power cords can cause short circuits. Close unused connectors with end caps intended for this purpose (www.thomann.de).
Installation Always work from a stable platform whenever installing, moving or servicing the unit. In doing so, the area underneath the unit must be cordoned off. Please note that this device must not be connected to a dimmer.
Starting up 5 Starting up Create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards.
Starting up Connections in DMX mode Connect the DMX input of the device to the DMX output of a DMX controller or another DMX device. Connect the output of the first DMX device to the input of the second one, and so on to form a daisy chain. Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor (110 Ω, ¼ W).
Connections and controls 6 Connections and controls ) MENU UP ENTER DOWN DMX IN PUSH POWER IN 100-240V~50/60Hz 2bright Pint TW200 IP LED PAR $ POWER OUT 24 DMX OUT 2bright Pint TW200 IP $ ( ö # % & '
Connections and controls 1 Display and keypad [MENU] Activates the main menu, toggles between the menu levels or closes a submenu. [DOWN] Decreases the displayed value by one. [UP] Increases the displayed value by one. [ENTER] Opens a submenu or confirms a value. 2 [DMX OUT] DMX output, designed as 3-pin XLR panel socket (IP65) 3 Locking screws for the brackets.
Connections and controls 5 [POWER OUT] Lockable chassis socket (Power Twist TR1 IP65) for the power supply of another device 6 Bracket for floor placement or hanging 7 [POWER IN] Lockable chassis socket (Power Twist TR1 IP65) for the power supply of the device 8 [DMX IN] DMX input, designed as 3-pin XLR panel plug (IP65) 26 2bright Pint TW200 IP LED PAR
Operating 7 Operating 7.1 Starting the device Connect the device to the power supply to start operation. The device is immediately opera‐ tional. 7.2 Operating on the unit Navigating in the menu 1. Press [MENU] to activate the main menu. 2. Press again [MENU] to call up further menu items. 3. To activate the respectively shown menu item, press [ENTER]. 4. Press [UP] or [DOWN] to change the respectively indicated value. 5. Press [ENTER] to apply the displayed value. 6.
Operating All set values are retained even when you switch the device off and disconnect it from the mains.
Operating Setting the DMX address 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘DMX Address’ . Confirm with [ENTER]. 2. Use [UP] or [DOWN] to select the desired DMX address between ‘001’ and ‘512’ . 3. Press [ENTER] to accept the selection. This setting is only relevant when the device is controlled via DMX. Make sure that this number matches the configuration of your DMX controller. The following table shows the highest pos‐ sible DMX address for the various DMX modes.
Operating Mode Display Highest possible DMX address 5-channel, variant A ‘5CH A’ 508 5-channel, variant B ‘5CH B’ 508 9-channel ‘9CH’ 504 Setting the DMX mode 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘DMX Mode’ . Confirm with [ENTER]. 2. Use [UP] or [DOWN] to select the desired DMX mode (1, 2, 3, 5, or 9 channels). Depending on the selected mode, the display shows ‘1CH’ , ‘2CH A’ , ‘2CH B’ ‘3CH’ , ‘5CH A’ , ‘5CH B’ or ‘9CH’ . 3.
Operating Manual mode / stand-alone operation 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Stand Alone’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] to select the desired submenu or the desired value.
Operating Menu level 2 Menu level 3 Function ‘AutoFade’ ‘No fade’ "Automatic fade" function off ‘0.5s…30s’ Automatic fade out with a fade time of 0.5 s to 30 s. The settings of the dimmer and the strobe effect become ineffective. 3. Press [ENTER] to accept the selection. 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘Display Reverse’ . Confirm with [ENTER]. 3.
Operating Setting display illumination 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘Backlight’ . Confirm with [ENTER]. 3. Use [UP] or [DOWN] to choose between ‘On’ (display permanently on) and ‘Off’ (display turns off after a few seconds in case of inactivity). 4. Press [ENTER] to accept the selection.
Operating Setting the behaviour on DMX control failure 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘DMX Fail’ . Confirm with [ENTER]. 3. Use [UP] or [DOWN] to choose between ‘Hold Last’ , ‘Blackout’ and ‘Manual’ , to make the setting to be used when the DMX controller fails. The following sub menus are available: 4.
Operating Setting the dimmer curve DIMMER 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘Dimmer Curve’ . Confirm with [ENTER]. 3. Use [UP] or [DOWN] to select the desired dimmer curve.
Operating Menu level 3 Function Fade time 1 s: Rise time 2040 ms, fall time 2120 ms ‘Theatre’ without fade time: Rise time 1580 ms, fall time 1940 ms Fade time 1 s: Rise time 2230 ms, fall time 2280 ms ‘Stage2’ without fade time: Rise time 0 ms, fall time 1100 ms Fade time 1 s: Rise time 0 ms, fall time 1660 ms 4. 36 2bright Pint TW200 IP LED PAR Press [ENTER] to accept the selection.
Operating Setting the dimmer speed The dimmer speed can only be set for the ‘Stage2’ dimmer curve. 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘Dimmer Speed’ . Confirm with [ENTER]. 3. Use [UP] or [DOWN] to select a dimmer speed between 0.1…0.9 seconds and 1…10 sec‐ onds (display shows ‘0.1-0.9s’ … ‘1-10s’ ). 4. Press [ENTER] to accept the selection.
Operating Enabling keylock 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘Auto Lock’ . Confirm with [ENTER]. 3. Use [UP] or [DOWN] to choose between ‘On’ (keylock on) and ‘Off’ (keylock off). 4. Press [ENTER] to accept the selection. Simultaneously press [UP] and [DOWN] for 5 seconds if you want to activate the input while the keylock is activated.
Operating Setting fan mode 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘Fan Mode’ . Confirm with [ENTER]. 3. Use [UP] or [DOWN] to select the desired fan mode. The following sub menus are available: 4. Menu level 3 Function ‘Smart’ The fan speed is controlled automatically depending on the device temperature. ‘Silent’ The fan is off (silent mode).
Operating LED repetition rate (PWM) 40 2bright Pint TW200 IP LED PAR 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘PWM Rate’ . Confirm with [ENTER]. 3. Use [UP] or [DOWN] to select the value for the LED repetition rate. The following table shows the available options. Menu level 3 Function ‘900Hz’ PWM 900 Hz ‘1000Hz’ PWM 1.0 kHz ‘1100Hz’ PWM 1.1 kHz ‘1200Hz’ PWM 1.
Operating 4. Menu level 3 Function ‘2500Hz’ PWM 2.5 kHz ‘4000Hz’ PWM 4 kHz ‘5000Hz’ PWM 5 kHz ‘6000Hz’ PWM 6 kHz ‘10000Hz’ PWM 10 kHz Press [ENTER] to accept the selection.
Operating Resetting the device to factory defaults 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘Service’ . Confirm with [ENTER]. 3. Press [UP] or [DOWN] repeatedly until the display shows ‘Reset’ . Confirm with [ENTER]. ð You are prompted to enter a password. 4. Enter the password 11. 5. Press [ENTER]. ð The device is reset to factory default settings.
Operating Calibrating colour temperature 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] repeatedly until the display shows ‘Service’ . Confirm with [ENTER]. 3. Press [UP] or [DOWN] repeatedly until the display shows ‘Calibration’ . Confirm with [ENTER]. ð You are prompted to enter a password. 4. Enter the password 50. Confirm with [ENTER]. 5.
Operating Firmware version display 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘System Info’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] until the display shows ‘Firmware’ . ð The current firmware version is displayed. LED operating hours display 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘System Info’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] until the display shows ‘LED On Time’ .
Operating Device operating hours display 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘System Info’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] until the display shows ‘Operation Hour’ . ð The operation hours of the device are displayed. Show device temperature 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘System Info’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] until the display shows ‘Temperature’ .
Operating RDM function This device has an RDM function and supports the DMX512 standard. Any device with RDM can be recognized by the built-in UID code. 1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘System Info’ . Confirm with [ENTER]. 2. Press [UP] or [DOWN] until the display shows ‘RDM’ . ð The display shows the UID code.
Operating Parameter ID IDENTIFY_DEVICE Recognition command Sent Command Received Command * * SUPPORTED_PARAMETERS * SENSOR_DEFINITION * SENSOR_VALUE * DMX_PERSONALITY * DMX_PERSONALITY_DESCRIPTION * * RESET_DEVICE * FACTORY_DEFAULTS * 2bright Pint TW200 IP LED PAR 47
Operating 7.3 Menu overview DMX Address DMX Mode 001...512 Stand Alone 1CH Settings CTC OFF 2CH A 2700...5800K 2CH B 3CH WarmWhite System Info Display Reverse On/Off Backlight On/Off ColdWhite 0...255 Blackout 1100Hz Amber 0...255 Manual 1200Hz 0...255 Strobe 0...30Hz Linear 1400Hz Stage 1500Hz No fade TV 2500Hz 0,5s...30s Architectural 4000Hz Theatre 6000Hz Stage2 10000Hz Dimmer Speed 0,1-0,9s...
Operating 7.4 Functions in 1-channel DMX mode Channel Value Function 1 000…255 Blinder mode 7.
Operating Channel 50 Value Function 091…100 LED on 101…170 Strobe pulses, increasing speed 171…180 LED on 181…240 Random strobe effect, increasing speed 241…255 LED on 2bright Pint TW200 IP LED PAR
Operating 7.6 Functions in 2-channel DMX mode, variant B Channel Value Function 1 000…255 Dimmer intensity from dark (0) to bright (255) 2 000…031 No function 032…255 Colour temperature of 2700 K to 5800 K (see chart at Ä Chapter 7.11 ‘Colour temperature adjustment via DMX’ on page 65 7.
Operating Channel 3 52 Value Function 032…255 Colour temperature of 2700 K to 5800 K (see chart at Ä Chapter 7.
Operating 7.
Operating Channel Value Function 171…180 LED on 181…240 Random strobe effect, increasing speed 241…255 LED on 7.9 Functions in 5-channel DMX mode, variant B Channel Value Function 1 000…255 Dimmer intensity from dark (0) to bright (255) 2 000…031 No function 032…255 Colour temperature of 2700 K to 5800 K (see chart at Ä Chapter 7.
Operating Channel 4 Value Function 011…020 LED off 021…030 Single strobe pulse 031…090 Strobe effect, increasing speed 091…100 LED on 101…170 Strobe pulses, increasing speed 171…180 LED on 181…240 Random strobe effect, increasing speed 241…255 LED on Dimmer curves 000…010 Default setting of the device 011…020 Dimmer curve ‘Linear’ 021…040 Dimmer curve ‘Stage’ 041…060 Dimmer curve ‘TV’ 2bright Pint TW200 IP LED PAR 55
Operating Channel 56 Value Function 061…080 Dimmer curve ‘Architectural’ 081…100 Dimmer curve ‘Theatre’ 101…120 Dimmer curve ‘Stage2’ 121 Delay 0.1 s 122 Delay 0.2 s 123 Delay 0.3 s 124 Delay 0.4 s 125 Delay 0.5 s 126 Delay 0.6 s 127 Delay 0.7 s 128 Delay 0.8 s 129 Delay 0.9 s 130 Delay 1.
Operating Channel 5 Value Function 131 Delay 1.5 s 132 Delay 2.0 s 133 Delay 3.0 s 134 Delay 4.0 s 135 Delay 5.0 s 136 Delay 6.0 s 137 Delay 7.0 s 138 Delay 8.0 s 139 Delay 9.
Operating Channel 58 Value Function 011…020 900 Hz 021…030 1000 Hz 031…040 1100 Hz 041…050 1200 Hz 051…060 1300 Hz 061…070 1400 Hz 071…080 1500 Hz 081…090 2500 Hz 091…100 4000 Hz 101…110 5000 Hz 111…120 6000 Hz 121…130 10,000 Hz 131…140 Default setting of the device 2bright Pint TW200 IP LED PAR
Operating Channel Value Function Fan mode 7.
Operating Channel Value Function 3 000…255 Intensity warm white (0 %…100 %) 4 000…255 Intensity amber (0 %…100 %) 5 Stroboscope 6 60 000…010 LED on 011…020 LED off 021…030 Single strobe pulse 031…090 Strobe effect, increasing speed 091…100 LED on 101…170 Strobe pulses, increasing speed 171…180 LED on 181…240 Random strobe effect, increasing speed 241…255 LED on 000…255 Blinder mode, overrides channels 2, 3, and 4 2bright Pint TW200 IP LED PAR
Operating Channel Value Function 7 000…031 No function 032…255 Colour temperature of 2700 K to 5800 K (see chart at Ä Chapter 7.11 ‘Colour temperature adjustment via DMX’ on page 65 8 Dimmer curves 000…010 Default setting of the device 011…020 Dimmer curve ‘Linear’ 021…040 Dimmer curve ‘Stage’ 041…060 Dimmer curve ‘TV’ 061…080 Dimmer curve ‘Architectural’ 081…100 Dimmer curve ‘Theatre’ 101…120 Dimmer curve ‘Stage2’ 121 Delay 0.1 s 122 Delay 0.
Operating Channel 62 Value Function 123 Delay 0.3 s 124 Delay 0.4 s 125 Delay 0.5 s 126 Delay 0.6 s 127 Delay 0.7 s 128 Delay 0.8 s 129 Delay 0.9 s 130 Delay 1.0 s 131 Delay 1.5 s 132 Delay 2.0 s 133 Delay 3.0 s 134 Delay 4.0 s 135 Delay 5.
Operating Channel 9 Value Function 136 Delay 6.0 s 137 Delay 7.0 s 138 Delay 8.0 s 139 Delay 9.
Operating Channel Value Function 061…070 1400 Hz 071…080 1500 Hz 081…090 2500 Hz 091…100 4000 Hz 101…110 5000 Hz 111…120 6000 Hz 121…130 10,000 Hz 131…140 Default setting of the device Fan mode 64 141…150 Fan mode ‘Silent’ 151…160 Fan mode ‘Smart’ 161…170 Fan mode ‘Max’ 2bright Pint TW200 IP LED PAR
Operating Channel 7.
Operating Colour temperature Cold white Warm white Amber DMX value 3200 K 000 255 020 067…073 3300 K 000 255 000 074…080 3400 K 022 255 000 081…087 3500 K 034 255 000 088…094 3600 K 048 255 000 095…101 3700 K 068 255 000 102…108 3800 K 080 255 000 109…115 3900 K 091 255 000 116…122 4000 K 115 255 000 123…129 4100 K 130 255 000 130…136 4200 K 150 255 000 137…143 4300 K 170 255 000 144…150 4400 K 200 255 000 151…157 66 2bright Pint TW200
Operating Colour temperature Cold white Warm white Amber DMX value 4500 K 230 255 000 158…164 4600 K 255 240 000 165…171 4700 K 255 220 000 172…178 4800 K 255 180 000 179…185 4900 K 255 160 000 186…192 5000 K 255 130 000 193…199 5100 K 255 105 000 200…206 5200 K 255 090 000 207…213 5300 K 255 070 000 214…220 5400 K 255 060 000 221…227 5500 K 255 045 000 228…234 5600 K 255 030 000 235…241 2bright Pint TW200 IP LED PAR 67
Operating Colour temperature Cold white Warm white Amber DMX value 5700 K 255 015 000 242…248 5800 K 255 000 000 249…255 68 2bright Pint TW200 IP LED PAR
Technical specifications 8 Technical specifications Light source 308 mm Optical properties DMX IN MENU ENTER 234 mm POWER IN 100-240V~50/60Hz 2bright Pint TW200 IP DMX OUT POWER OUT 249 mm UP DOWN PUSH 1 × 3in1 WW/CW/A COB LED, 200 W Colour temperature 2700 K…5800 K Beam angle 50° CRI 95 Repetition rate 900 Hz…10 kHz Control DMX RDM Buttons and display Number of DMX channels 1, 2, 3, 5, 9 Input connections Power supply Lockable input socket Power Twist TR1 IP65 DMX control XLR
Technical specifications DMX control Power consumption 135 W Supply voltage 100 - 240 V Degree of protection IP65 Mounting options Hanging, standing Dimensions (W × H × D), with bracket 234 mm × 308 mm × 249 mm Weight 4.
Technical specifications Further information Construction Outdoor housing, cannon Number of LEDs 1 Colour mixture CW/WW/A LED type COB Floor housing Yes Fanless No Remote control Not possible Wireless DMX No Housing colour Black 2bright Pint TW200 IP LED PAR 71
Plug and connection assignments 9 Plug and connection assignments Introduction This chapter will help you select the right cables and plugs to connect your valuable equip‐ ment so that a perfect light experience is guaranteed.
Troubleshooting 10 Troubleshooting NOTICE! Possible data transmission errors For error-free operation make use of dedicated DMX cables and do not use ordi‐ nary microphone cables. Never connect the DMX input or output to audio devices such as mixers or ampli‐ fiers. In the following we list a few common problems that may occur during operation.
Troubleshooting Symptom Remedy The unit does not work, no light. Check the mains connection and the fuse. No response to the DMX con‐ troller. 1. Check the DMX ports and cables for proper connection. 2. Check the address settings and the DMX polarity. 3. Try using another DMX controller. 4. Check to see if the DMX cables run near or alongside to high voltage cables that may cause damage or interfer‐ ence to DMX interface circuits.
Cleaning 11 Cleaning Optical lenses Clean the optical lenses, that are accessible from the outside, regularly in order to optimize the light output. The frequency of cleaning depends on the operating environment: wet, smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device. n Clean with a soft cloth using our lamp and lens cleaner (item no. 280122). n Always dry the parts carefully.
Protecting the environment 12 Protecting the environment Disposal of the packaging mate‐ rial For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling. Please follow the notes and markings on the packaging.
Notes 2bright Pint TW200 IP LED PAR 77
Notes 78 2bright Pint TW200 IP LED PAR
Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.