User Manual

70 MINI USER’S MANUAL
70-MINI V.01.00 (01/07) 120009-0B.pdf IKUSI se reserva el derecho de modificar esta información sin previo aviso. 10
70-MINI V.01.00 (01/07) 120009-0B.pdf IKUSI reserves the right to modify this information without prior notification.
5.- RECEIVERS
5.1.- TYPE OF RECEIVERS: CONNECTIONS BLOCK DIAGRAMS
R70MP10: PWM OUTPUT RECEIVER (10 OUTPUTS).
R70MR11: RECEIVER WITH OUTPUT RELAYS (11 OUTPUTS).
R70MR06: RECEIVER WITH OUTPUT RELAYS (6 OUTPUTS).
The voltage DC of the power supply (from 9v to 35v
DC, is conducted to the common wiring of the 10 output
switches (OUT1 until OUT10), through a SAFETY
switch which guarantees the output disconnection in
case of breakdown of some of the outputs. The
“RELAY” (STOP) switches between 2 fixed positions
NO (normally opened) and NC (normally closed). An
“LIB ID” function, with ID release pushbutton is
available on the electronic board, and it can be used in
case of transmitter’s breakdown. The ID release can be
also performed from the transmitter with a special
function.
RL-1: Power supply plug in terminals (24,48,115
and 230 V AC). Please note –see table- the right
fuse values depending on the input voltage.
RL-2: Plug in identified connection terminals, 1st
and 2nd speed (K1….K11) and START relay.
RL-3: Plug in terminal for connecting the STOP
relay (NO Cat.3 EN-954-1)
LIB-ID: pushbutton to release the ID from the
receiver.
EP70: On board plug in connector to connect an
external EP70 (External EEPROM).
RL-1: Power supply plug in terminals (24,48,115 and 230
V AC). Please note –see table- the right fuse values
depending on the input voltage.
RL-2: Plug in identified connection terminals, 1st and 2nd
speed, HOISTING; TROLLEY TRAVELLING; SAFETY;
START: STOP (Cat.3 EN-954)
LIB-ID: pushbutton to release the ID from the receiver.
EP70: On board plug in connector to connect an external
EP70 (External EEPROM).
- Remember to connect the ground cable.
- Only use fireproof cables for connections.
- Select the appropriate voltage on the receiver, (230, 115 or 48 Vac). R70MR11 and R70MR06
models.