User Manual

GB
9
Connecting The Oven To The Mains
For connecting use a flexible rubber cable of the H05SS-F type (3x2 5 mm
2
min)
remembering to make it long enough to allow the oven to be removed from its housing
unit when maintenance work is required To connect the cable to the oven proceed as
follows (see figure):
1 Remove the two upper oven covers (1) by unfastening the relative self-tapping
screws (2). Unfasten the nut (3) for the cable holder and feed the cable through the
hole leaving enough cable slack to to avoid stretching.
2 Remove about 12 cm of outside insulation from the cable and shorten the two active
wires (live and neutral) to 6cm. Leave the length of the earth wire as it is. Remove
about 1cm of insulation from each of the three wires and then connect each wire to
the terminal block. Ensure that each wire is connected appropriately (L is for the
Live wire, N is for the Neutral wire and the earth wire is indicated with the traditional
dashed triangle).
3 Tighten the two cable holder screws so as to ensure that the mains cable is held
firmly in place.