Operating Instructions and Installation Instructions

Examples:
A. Flame with excess of air: it is small, tight and
separated. Move forward the cylindrical sleeve R
placed in front of the injector.
B. Flame with lack of air; it is floppy with yellow
streaks. Move backward the cylindrical sleeve R
placed in front of the injector.
C. Normal flame: its colour is light blue
Low Flame Adjustment of Burners
When installing the appliance it is recommended to
check that the burner minimum speed
(Low Flame Setting) has been correctly adjusted.
If it is necessary to change the type of gas,
adjustment of the low flame setting must be
completed by the installer. To adjust the minimum
setting for the burners the following steps must
be complete.
Recommended Bypass
(Low Flame Settings) Turns from fully in position
installation instructions
Built-in cooktops
24 ILVE Built-in Cooktop Operating & Installation Manual