Conversion Kit Instruction for Majestic II

BURNER
SR
R
P
DCC
DUAL
DUAL (only AUX)
SR
R
P
DCC
DUAL
DUAL (only AUX)
GAS
NATURAL (A)
NATURAL (A)
NATURAL (A)
NATURAL (A)
NATURAL (A)
NATURAL (A)
PROPANE (E)
PROPANE (E)
PROPANE (E)
PROPANE (E)
PROPANE (E)
PROPANE (E)
ORIFICE SIZE
(1/100) mm
120
145
145
190
75+190
75
75
90
92
117
44+120
44
SIMMER RATE
[Btu/h]
1400
2000
3100
6200
6000
900
1400
2000
3100
6200
6000
900
BY-PASS ORIFICE
SIZE
(1/100) mm
Adj.*
Adj.*
Adj.*
Adj.*
Adj.*
Adj.*
32
40
52
75
27+60
27
IMPUT RATE
[Btu/h]
7000
10500
10500
16500
20000
2800
7000
10500
10500
16500
20000
2800
CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the
conversion. The kit for the gas conversion of the burners is relevant to the model of the appliance indicated on the
label sti-cking to the first page of this booklet. The kit contains the number and type of orifices necessary for the
conversion, all the necessary instructions, a label to stick onto the old one to show the new setting (see table 2) and
the label to be completed by the technician who performs the conversion. The appliance is pre-adjusted in factory
for the gas indicated on the label put on the gas inlet pipe. For the conversion to another gas refer to table 3.
The positions, types of burner and relevant orifices for the models included in this booklet are depicted in table 3.
The only operation to perform after conversion to a gas different from that shown on the rating plate/label is the
adjustment of the minimum gas flow. (See page 3 of this leaflet). After conversion remember to put the new gas
indication label (supplied in the conversion kit) as close as possible to the existing rating plate, then check the
regular ignition of the burners (see pages 3 and 4 of this leaflet, “Lighting the burners”).
If the appliance is installed at an altitude exceeding 2,000 ft, a new set of orifices can be requested from the
supplier or an authorised service parts distributor.
NOTE: Due to the lower atmospheric pressure at higher altitudes, foods tend to take longer to cook. Therefore,
recipe adjustments should be made in some cases. In general, no recipe adjustment is necessary for yeast-risen
baked goods, although allowing the dough or batter to rise twice before the final pan rising develops a better
flavor. Try making the adjustments below for successful recipes. Take note of the changes that work best and mark
your recipesaccordingly. You may also consult a cookbook on highaltitude cooking for specific recommendations.
WARNING: after first installation of the appliance, after gas conversion kit installation or after any service
intervention concerning main gas parts of the appliance, make the leak test using water with soap on the gas
connections in order to verify the correct installation. Do not use fire for gas leak testing. The test is valid if there is no
bubble or foam build-up during a period of one minute.
1
CHANGING THE INJECTORS
WARNING
"This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable codes
and requirements of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage, personal injury or
loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit."