This appliance shall only be installed by an authorized person. This appliance shall be installed in accordance
with the manufactures installation instructions, IMPORTANT: this appliance must be installed in accordance with the
norms in force of the country concerned.
The installation of this appliance must conform to local codes and ordinances. In the absence of local codes.
Installations must conforms to American National Standards, National Fuel Gas Code ANSI Z223.1-NFPA54.
If local codes permit, a exible metal appliance connection with the new AGA or CGA certi ed design, max. 5
feet (1,5m) long, ½” I.D. recommended for connecting this cooktop to the gas supply line. Do not bend or dama-
ge the exible connector when moving the cooktop. The pressure regulator has ½” female pipe thread. You will
need to determine the tting required, depending on the size of your gas supply line, the exible metal connector
and the shutoff valve.
The appliance , when installed, must be electrically grounded in accordance with local codes or, in absence
of local codes, with the National Electrical Code, ANSI/NFPA 70, CSA C22.1-02.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressure in excess of ½psi (3,5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff alve
during any pressure testing of the gas supply piping system at test pressure equal to or less than ½psi (3,5kPa).
For use with a pressure regulator. The regulator supplied must be used with this appliance; it shall be properly in-
stalled in order to be accessible when appliance is installed in de nitive position.
The gas appliance pressure regulator must be set for the gas with which the appliance is used.
This appliance can be used with Natural gas and Propane. It is shipped from the factory adjusted for use with Na-
tural gas: CONVERSION FIXED ORIFICES ARE LOCATED IN THE LITERATURE PACK SUPPLIED WITH THE UNIT.
Injectors kit for the change of type of gas are contained inside the package jointly with the hob installation kit
and Instruction booklet. The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator
is 14” water column (5kPa). The minimum gas supply pressure for checking the regulator setting shall be at least
1”w.c.(249Pa) above the inlet speci ed manifold pressure to the appliance (this operating pressure is 5”w.c. for
Natural Gas and 10”w.c. for Propane.All opening and holes in the wall and  oor, back and under the appliance
shall be sealed before installation of the appliance.
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the appliance
for the purpose of turning on or shutting off gas to the appliance.
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation.
The appliances should not be installed with a ventilation system that blows air downward toward the range.
WARNING: Before removing the appliance disconnect the electric power supply cable and close the relevant
shut off valve. Make sure that the electric power supply cable is not damaged during cleaning/maintenance
operations. When repositioning the appliance make sure that the anti-tip device is correctly tted again as
before removal.
NOTE 1:possible risks may result from abnormal usage, including excessive
loading of the oven door.
NOTE 2: reinstall the appliance in accordance with the manufacturer’s
instructions to avoid the risk of tip-over
INSTALLATION INSTRUCTIONS
Product Model/Serial Label
and Rating Label Locations