User Manual

Charging of the Pb battery
Charging of the Pb battery
Battery
type
DEC
Pb CHARGE
4.0A 12.0V(6P)
Pb-6 4.0A 12.59V
CHG 022:43 00682
-
Batt type
Stop
Elapsed
time
INC
+
Charge
current
Battery
voltage
DEC
Start
Enter
-
‘>3 seconds’
INC
+
Charged
capacity
Set up the charge current on the left and nominal voltage on the right.
Range of current is 0.1-5.0A, the voltage should match the battery being
charged. Press START/ENTER key for more than 3 seconds to start
charging.
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press START/ENTER key
again to store the parameter value you set. Press BATT TYPE/STOP key
to end the program.
Discharging of t he Pb batteryy
DEC
Pb DISCHARGE
1.0A 12.0V(6P)
-
Batt type
Stop
INC
+
DEC
Start
Enter
-
‘>3 seconds’
INC
+
Set up the charge current on the left and nominal voltage on the right.
Range of discharge current is 0.1-5.0A, the voltage should match the
battery being charged. Press START/ENTER key for more than 3
seconds to start charging.
Pb-6 0.4A 12.59V
DSC 022:43 00682
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press START/ENTER key
again to store the parameter value you set. Press BATT TYPE/STOP key
to end the program.
Battery
type
Elapsed
time
Discharge
current
Battery
voltage
Discharged
capacity
24