Operation Manual
Table Of Contents
- 1. Quick Start
- 2. Introduction
- 3. Getting Started
- 3.1. Installation
- 3.2. Injector Features
- 3.3. Symbols
- 3.3.1. Symbols used in this manual
- 3.3.2. Symbols used on labelling
- 3.3.3. Handswitch and Footswitch
- 3.3.4. Icons and Buttons used on the Injector Touch Screen Graphical Interface
- 3.3.5. Injector Buttons
- 3.3.6. Remote Control Symbols and Buttons
- 3.3.7. Injector Visual Indicators
- 3.3.8. Icons and Buttons used on the RCU Touch Screen Graphical Interface
- 4. Clinical Information
- 5. Operation Description
- 5.1. Turning the System On for the First Time
- 5.2. Syringe, Quick Fill Tube, Fill Spike, and Connector Tubes
- 5.3. Filling a Syringe Using a Quick Fill Tube (QFT) or Fill Spike on the Injector
- 5.4. [Optional] Off-line Filling
- 5.5. Connector Tube Installation
- 5.6. Dismounting a Syringe
- 5.7. Performing an injection
- 5.8. Programming
- 5.9. Options Menu
- 5.10. [RCU models] Operation Description with Remote Control Unit
- 5.10.1. RCU Features–
- 5.10.2. The Injector and the RCU
- 5.10.3. Turning the System On / Off
- 5.10.4. Injector Controller Application
- 5.10.5. Filling State
- 5.10.6. Routine Protocol
- 5.10.7. Arming
- 5.10.8. Check for Air
- 5.10.9. Starting the Injection
- 5.10.10. Injection in Progress
- 5.10.11. Injection Control Buttons
- 5.10.12. Injection Review
- 5.10.13. Protocol Edit
- 5.10.14. Edit Lock
- 5.10.15. Parameter Value Edit
- 5.10.16. Injecting remaining volume
- 5.10.17. Edit Phase Type
- 5.10.18. Open Protocol
- 5.10.19. Protocol Save
- 5.10.20. Common Injecting Alarms / Warnings
- 5.10.21. RCU Manager
- 5.10.22. RCU Setup
- 5.10.23. History Viewer
- 5.10.24. Protocol Manager
- 5.10.25. eGFR (glomerular filtration rate) Calculator
- 5.11. [Optional] DC200 Scanner Interface
- 5.12. [Optional] Protocol Assistance Tool (PAT)
- 6. Cleaning and Maintenance
- 7. Trouble-shooting
- 8. Specifications
- 8.1. Dimensions
- 8.2. Mechanical
- 8.3. Functional
- 8.4. Controls
- 8.5. Environmental
- 8.6. Electrical
- 8.7. Connectors
- 8.8. IEC 60601-1 Classifications
- 8.9. Ground Continuity
- 8.10. RoHS Statement
- 8.11. IEC60601-1-2:2014 (4th Ed) Compliance
- 8.12. Models
- 8.13. Accessories
- 8.14. Manufacturer’s Software License Information
- 8.15. FCC Statement
- 9. Index
MEDRAD
®
Salient Operation Manual 13
3.3. Symbols
3.3.1. Symbols used in this manual
Warnings advise of circumstances that could result in injury or death to the patient or operator. Read
and understand all warnings before operating the injector. Consult accompanying documents/text.
The symbol is located throughout this manual and on the injector labelling as required.
Warning, biological hazard
Electrical Shock Hazard
Pinch Hazard
Cautions advise of circumstances that could result in damage to the injector. Read and understand all
cautions before operating the injector.
3.3.2. Symbols used on labelling
Do not dispose in municipal waste, in accordance with the DIRECTIVE 2002/96/EC OF
THE EUROPEAN PARLIAME
NT AND OF THE COUNCIL on waste electrical and
electronic equipment (WEEE).
Identifies the terminal which provides a connection between the injector and the
equipotential busbar of the electrical installation. The symbol is located on the base power
panel
Identifies switch position for disconnection from line power. The symbol is located on the
power switch on the base power panel.
I
Identifies switch position for connection to line power. The symbol is located on the power
switch on the base power panel.
Identifies type BF medical equipment complying with EN 60601-1 standards. The symbol is
located on the base power panel.
CLASS 1
Indicates the system is Class 1 medical equipment as defined by EN 60601-1 standards. The
symbol is located on the base power panel.
CB
Identifies circuit breaker. The symbol is located on the base power panel.
Identifies protective earth. The symbol is located within the base unit.