iMediaChassis Series • • • iMediaChassis/20 iMediaChassis/6 iMediaChassis/3 Operation Manual
FCC Radio Frequency Interference Statement Class A This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Warranty IMC Networks warrants to the original end-user purchaser that this product, EXCLUSIVE OF SOFTWARE, shall be free from defects in materials and workmanship under normal and proper use in accordance with IMC Networks' instructions and directions for a period of six (6) years after the original date of purchase. This warranty is subject to the limitations set forth below.
Table of Contents FCC Radio Frequency Interference Statement ........................................................ ii Class A ..................................................................................................................ii Class B ..................................................................................................................ii Warranty...............................................................................................................
iMediaChassis/3 Features ....................................................................................17 Alarm Reset, Last Gasp, and Temperature Gauge ............................................17 Alarm Reset Button .........................................................................................17 Last Gasp Alarm ..............................................................................................17 Temperature Gauge .................................................................
About the iMediaChassis/20 The iMediaChassis series is a modular chassis platform designed for use with IMC Networks’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/20 is a 3U high, Rackmountable chassis that features 20 slots for installing application series modules plus an additional slot for installing an SNMP Management Module. Power supply modules are user-replaceable and hotswappable.
Alarm Reset Button When one power supply module malfunctions, an audible alarm sounds indicating the loss of the power module. The alarm can be silenced by pressing the Alarm Reset Button, located next to the power connector on the power supply module. If this occurs, remove and replace the power supply module immediately. (LEDs on the Management Module and the power supply module itself also indicate power supply module failures.
SNMP Management Module LEDs The SNMP Management Module features several LEDs. The LED functions are: LNK/ACT Glows green when a link is established on port. Blinks green when data activity occurs. FDX/COL Glows yellow when port is in Full-Duplex mode. Blinks yellow when port is operating in HalfDuplex mode and collisions occur. TEMP Glows yellow when temperature of unit surpasses a user-defined level. PS Glows yellow when one module malfunctions. FAN A / FAN B Glows yellow when a fan malfunctions.
5. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. 6. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. 7.
Installing SNMP Management and Application Modules To install a module: 1. Remove the blank bracket (if present) covering the slot where the module will be installed. IMC Networks recommends installing blank brackets in unused module slots. 2. Slide the module into the chassis using the card guides. 3. Secure the module to the chassis by tightening the captive screw. (Refer to the documentation shipped with the module for configuration information.) 4.
Replacing Power Supply Modules User-Replaceable Power Supply Modules While power supply modules are redundant *, failed power supply modules should promptly be replaced to maintain network integrity and prevent data loss. To replace a power supply module: 1. 2. 3. 4. 5. Disconnect the power source from the power supply module. Remove the screws of the retainer plate (on some AC modules). Move the Power Supply Release switch toward the right or unscrew captive release screw.
Dual AC, Part Number 850-10956-2AC NOTE Do not mix AC and DC power supply modules.
Dual DC, Part Number 850-10960-2DC Power Supply Status LED PS Release Screw Power Supply Module 1 (PS1) Reset Alarm Switch Power Connector Power Supply Module 2 (PS2) Redundant DC Power Supply, Close-Up *Does not support redundancy.
iMediaChassis/20 Specifications Input Specifications Dual AC 100 to 240V AC, 50/60Hz, 3.5/1.5A Dual DC -48V DC, 5A ACDC 100 to 240V AC, 50/60HZ, 2A -48V DC, 4.4A Operating Temperature 0° C to 50° C (32° F to 122° F) Storage Temperature Dual AC & ACDC -20° C to 80° C (-4° F to 176° F) Dual DC -20° C to 60° C (-4° F to 140° F) Humidity 20 to 90% (non-condensing at 40° C) Shipping Weight 25 lbs (11.3 kg) Dimensions 5.2" x 19.0" x 13.8" (13.21cm x 48.26cm x 35.
About the iMediaChassis/6 The iMediaChassis series is a modular chassis platform designed for use with IMC Networks’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/6 is 1U high, Rackmountable and supports optional redundant power supply modules, as well as an SNMP Management Module. iMediaChassis/6 Features The iMediaChassis/6 series offers a line of models including single AC, single DC, dual AC and dual DC.
Last Gasp Alarm The iMediaChassis series includes the Last Gasp trap feature, “Remote Chassis Down”, which sends a Trap when the following occurs: • Both power supply modules malfunction • Both power supply modules are powered down • When the AC line fails Temperature Gauge The iMediaChassis/6 includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis. Users define a threshold for chassis temperature via SNMP.
SNMP Management Module LEDs The SNMP Management Module features several LEDs. The LED functions are: LNK/ACT Glows green when a link is established on port. Blinks green when data activity occurs. FDX/COL Glows yellow when port is in Full-Duplex mode. Blinks yellow when port is operating in HalfDuplex mode and collisions occur. TEMP Glows yellow when temperature of unit surpasses a user-defined level. PS Glows yellow when one power supply module malfunctions.
5. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. 6. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. 7.
DC Power Wiring, Replacing Power Supply Modules and Fans DC Power Supply Wiring Instructions The following diagram shows the wiring configurations for -48 VDC power supply modules for the iMediaChassis/6. User-Replaceable Power Supply Modules The iMediaChassis/6 ships from IMC Networks with one or two power supply modules installed depending on the model. Chassis ordered with one power supply come with a filler tray installed in the second slot. To install a second power supply: 1. 2. 3.
SNMP Management Modules include two twisted pair ports, one for management and one reserved for future use. The Management Module also features a DB-9 serial port, and supports SNMP V1/V2c. Installing Management and Application Modules Installing Applications Modules To install a module: 1. Remove the blank bracket (if present) covering the slot where the module will be installed. IMC Networks recommends installing blank brackets in unused module slots. 2.
iMediaChassis/6 Specifications Input Specifications AC DC 100 to 240V AC, 50/60Hz, 1A -48V DC, 2A Operating Temperature: AC DC -25° C to 50° C (-130° F - 122° F) -40° C to 100° C (-40° F - 212° F) Storage Temperature: AC DC -40° C to 85° C (-40° F - 185° F) -55° C to 125° C (-67° F - 257° F) Humidity 5 - 95% (non-condensing); 0-10,000 ft. altitude Shipping Weight 13 lbs (5.90 kg) Dimensions 1.75” x 17.35” x 10.65” (4.45cm x 44.07cm x 27.
About the iMediaChassis/3 The iMediaChassis series is a modular chassis platform designed for use with IMC Networks’ Simple Network Management Protocol (SNMP) manageable series of modules. The iMediaChassis/3 is a 1U high, Rackmountable, capable of offering redundant power supply modules, and supports an SNMP Management Module. iMediaChassis/3 Features The iMediaChassis/3 series offers a line of models including single AC, single DC, dual AC, dual DC and ACDC version.
Temperature Gauge The iMediaChassis/3 includes a temperature monitoring gauge with a heat sensor on the backplane of the chassis. Users define a threshold for chassis temperature via SNMP. If the chassis’ temperature rises above the specified level, the SNMP agent sends a trap (configured in iView²) to the administrator. There is also an LED indicator on the SNMP Management Module for chassis temperature.
5. If mounting the chassis on a wall, place two #10 panhead screws (not supplied) on the wall according to the distance of the holes on the chassis, and then hang the unit on the screws. 6. All versions are intended for use in a Restricted Access Location (RAL). 7. A readily accessible disconnect device shall be incorporated in the building installation wiring. 8. A suitable listed circuit breaker shall be provided in the building installation as the unit’s disconnect device.
Power Supply Modules Power supply modules in all models of the iMediaChassis/3 are fixed, and not enduser replaceable. Fans The iMediaChassis/3 includes temperature-triggered fans. When the temperature of the chassis reaches 40° C, the two fans activate to cool the chassis. The fans’ operation can be tested by holding the Alarm Reset Button down for 4 to 5 seconds. The fans will activate and then they will turn off when the button is released. If the fans do not activate, contact IMC Networks.
SNMP Write Lock The SNMP Write Lock switch is located on the back of the iMediaChassis/3. The SNMP Write Lock switch prevents a new management board from re-configuring the application module settings (e.g., the status of features such as LinkLoss, FiberAlert, Force mode, etc.) made via SNMP on any previous Management Modules. NOTE Leave this switch in the NORMAL position during day-to-day operation; the LOCKED position should only be used when changing the SNMP management board.
LNK/ACT Glows green when a link is established on port. Blinks green when data activity occurs. FDX/COL Glows yellow when port is in Full-Duplex mode. Blinks yellow when port is operating in HalfDuplex mode and collisions occur. TEMP Glows yellow when temperature of unit surpasses a user-defined level. PS Glows yellow when one power supply module malfunctions. FAN A / FAN B Glows yellow when a fan malfunctions.
iMediaChassis/3 Specifications Input Specifications AC 100 to 240V AC, 50/60Hz, 0.75A DC 35V DC to 75V DC Max, 1.6A Operating Temperature AC DC 0° C to 50° C (32° F to 122° F) -40° C to 50° C (-67° F to 122° F) Storage Temperature AC DC -40° C to 85° C (-40° F to 185° F) -55° C to 125° C (-40° F to 212° F) Humidity: 5 to 95% (non-condensing); 0 to 10,000 ft. altitude Shipping Weight: 5 lbs (2.3 kg) Dimensions: H=1.73” W=7.50” D=8.74” (4.4 x 19.0 x 22.
IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020 E-Mail: techsupport@imcnetworks.com Web: www.imcnetworks.com WARNING Disconnect all power supplies before servicing.
Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products 1. Do not remove unit from its protective packaging until ready to install. 2. Wear an ESD wrist grounding strap before handling any module or component.
Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. CE: The products described herein comply with the Council Directive on Electromagnetic Compatibility (2004/108/EC) and the Council Directive on Electrical Equipment Designed for use within Certain Voltage Limits (2006/95/EC). Certified to Safety of Information Technology Equipment, Including Electrical Business Equipment. For further details, contact IMC Networks.
19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2010 IMC Networks. All rights reserved. The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any errors that may appear in this document. iMediaChassis Series is a trademark of IMC Networks. Other brands or product names may be trademarks and are the property of their respective companies.