The ideal solution for extending PBX or legacy
Telco circuits over fiber optics in the local loop
and or long-haul applications.
Product Overview
SNMP-manageable, the iMcV-T1/E1/J1 converter series of modules
extend1.544 Mbps T1/J1 and 2.048 Mbps E1 copper-based PBX,
router and switch circuits over regular duplex fiber or single-strand fiber
optics. Supporting fiber distances of up to 80 km, the iMcV-T1/E1/J1
series of converters include built-in jitter removal, line integrity testing,
diagnostic tools (Loopback mode and Transmit Data Source) and remote
management features.
Select from the iMcV-T1/E1/J1, offering standard repeater-like functionality,
or the IE-iMcV-T1/E1/J1-LineTerm which incorporates advanced features
such as Line Terminating functionality and config control, support for both
Alarm Indication Signals (AIS) and Remote Alarm Indications (RAI). Both
versions are designed to be installed in pairs.
The IE-iMcV-T1/E1/J1 LineTerm modules are installed as a HOST-
REMOTE pair and can be remotely managed when the HOST is installed
in an iMediaChassis with an SNMP–Management Module. This enables
network managers to conduct loopback testing, to monitor, and to manage
units located up to 80 km away.
Features
Switch Selectable Protocol
Operates at (T1/J1 1.544 Mbps) and
(E1 2.048 Mbps)
Two versions to choose from:
Standard version – offers repeater-like
functionality
Line Terminating version – supports “Telco-like”
features, including Alarm Indication Signals
(AIS) and Remote Alarm Indications (RAI)
Management
Conduct Loopback tests, monitor/manage units
via GUI-based iView2
Remote unit supports secure, out-of-band
management
• Diagnostic LEDs
Offers more fiber choices
Available for multi-mode or single-mode fiber
Single-strand fiber versions
Supports distances up to 80 km
Eases troubleshooting
Loopback testing modes, plus SNMP
management and LEDs, assist in diagnosing
problems on fiber optic or copper networks
Supports fiber and coax remote loopback control
Transmit Data Source diagnostic tool sends data
as unframed all ones, a pattern of alternating
ones and zeros, or a Pseudorandom Bit
Sequence (PRBS). A built-in PRBS signal
detector makes testing even easier.
LED display for monitoring of line diagnostics
iMcV-T1/E1/J1 and IE-iMcV-T1/E1/J1-LineTerm with Config Control
Managed Auto Cross
Auto
Negotiation
Fiber Alert
FIBER
LOS
X
X
LINK
LINK
Link Loss
X
X
LOS
T1/E1/J1 Modular Converters
Application Example
Extend T1/E1/J1 signals up to 80 km over fiber using point to point
iMcV-T1/E1/J1 modules. In the example below, PBX traffic from a local
office is sent over fiber to a remote data center.
850-14198
iMcV-T1/E1/J1, TP/Fiber-MM850-ST, 2 km
850-14199
iMcV-T1/E1/J1, TP/Fiber-MM850-SC, 2 km
850-14200
iMcV-T1/E1/J1, TP/Fiber-MM1300-ST, 5 km
850-14201
iMcV-T1/E1/J1, TP/Fiber-MM1300-SC, 5 km
850-14202
iMcV-T1/E1/J1, TP/Fiber-SM1310/PLUS-ST, 40 km
850-14203
iMcV-T1/E1/J1, TP/Fiber-SM1310/PLUS-SC, 40 km
850-14204
iMcV-T1/E1/J1, TP/Fiber-SM1310/LONG-ST, 80 km
850-14205
iMcV-T1/E1/J1, TP/Fiber-SM1310/LONG-SC, 80 km
850-14206
iMcV-T1/E1/J1, TP/Fiber-SM1550/LONG-SC, 80 km
Single-Strand Fiber
850-14288
iMcV-T1/E1/J1, TP/SSFiber-MM1310-SC (1310xmt/1550rcv),
2 km
850-14289
iMcV-T1/E1/J1, TP/SSFiber-MM1550-SC (1550xmt/1310rcv),
2 km
850-14290
iMcV-T1/E1/J1, TP/SSFiber-SM1310-SC (1310xmt/1550rcv),
20 km
850-14291
iMcV-T1/E1/J1, TP/SSFiber-SM1550-SC (1550xmt/1310rcv),
20 km
850-14292
iMcV-T1/E1/J1, TP/SSFiber-SM1310/PLUS-SC
(1310xmt/1550rcv), 40 km
850-14293
iMcV-T1/E1/J1, TP/SSFiber-SM1550/PLUS-SC
(1550xmt/1310rcv), 40 km
850-14294
iMcV-T1/E1/J1, TP/SSFiber-SM1310/LONG-SC
(1310xmt/1550rcv), 60 km
850-14295
iMcV-T1/E1/J1, TP/SSFiber-SM1550/LONG-SC
(1550xmt/1310rcv), 60 km
iMcV-T1/E1/J1 Repeater Modules
850-18101
iMcV-T1/E1/J1-LineTerm TP/Fiber-MM850-ST, 2 km
850-18102
iMcV-T1/E1/J1-LineTerm TP/Fiber-MM850-SC, 2 km
850-18103
iMcV-T1/E1/J1-LineTerm TP/Fiber-MM1300-ST, 5 km
850-18104
iMcV-T1/E1/J1-LineTerm TP/Fiber-MM1300-SC, 5 km
850-18105
iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/PLUS-ST, 40 km
850-18106
iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/PLUS-SC, 40 km
* 850-18107
iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/LONG-ST, 80 km
* 850-18108
iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1310/LONG-SC, 80 km
850-18111
iMcV-T1/E1/J1-LineTerm TP/Fiber-SM1550/LONG-ST, 80 km
Single-Strand Fiber
850-18120
iMcV-T1/E1/J1-LineTerm TP/SSFiber-MM1310-SC
(1310xmt/1550rcv), 2 km
850-18121
iMcV-T1/E1/J1-LineTerm TP/SSFiber-MM1550-SC
(1550xmt/1310rcv), 2 km
850-18122
iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310-SC
(1310xmt/1550rcv), 20 km
850-18123
iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550-SC
(1550xmt/1310rcv), 20 km
850-18124
iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310/PLUS-SC
(1310xmt/1550rcv), 40 km
850-18125
iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550/PLUS-SC
(1550xmt/1310rcv), 40 km
850-18126
iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1310/LONG-SC
(1310xmt/1550rcv), 60 km
850-18127
iMcV-T1/E1/J1-LineTerm TP/SSFiber-SM1550/LONG-SC
(1550xmt/1310rcv), 60 km
IE-iMcV-T1/E1/J1 Line Terminating
with Config Control Modules
Physical Specifications
Fiber Types Supported
• 50/125μm or 62.5/125μm multi-mode fiber
• 9/125μm single-mode fiber
Available for single-strand fiber
Connectors:
RJ-48, ST and SC
Regulatory Approvals:
FCC Class A, UL/cUL, CE, CSA, CB
Operating Temperature:
+32° to +122°F (0° to +50°C)
Storage Temperature:
-13° to +158°F (-25° to +70°C)
Humidity:
5 to 95% (non-condensing)
Altitude:
0 to 10,000 ft.
Dimensions
4.19”H x 0.78”W x 2.75”D (10.74 x 2 x 7.05 cm)
Power Rating:
5V
Shipping Weight:
0.30 lbs (0.11 kg)
*Certified at 40 km, 80 km is achievable
CWDM versions available,
See website for details
850-18100
IE-iMcV-T1/E1/J1-LineTerm, TP/SFP
(requires one SFP/155-ED Module required)
IE-iMcV-T1/E1/J1-LineTerm, With
Config Control TP/SFP
Configuration Control
Is available on select models of the IE-iMcV-T1/E1/J1 Line Term
and IE-iMcV-T1/E1/J1 TP/SFP. Its main function is to assist the
end-user by retaining the latest configuration regardless of how
the initial configuration was setup, whether through DIP Switch
settings or the SNMP Management Module’s configuration.
Config
Control
Config
Control
natin
g
g
g
g
g
g
g
g
g
g
s
NEW!
NEW!
Use with Chassis Platform
iMediaChassis Series, See Page 45
MediaChassis Series, See Page 46
IE-MediaChassis Series, See Page 46