IE-MediaChassis/2 (DC) Operation Manual
FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents FCC Radio Frequency Interference Statement ........................................................ ii Warranty................................................................................................................ ii About the IE-MediaChassis/2 (DC)..........................................................................1 Installing the IE-MediaChassis/2 (DC)......................................................................1 Configuring and Installing Modules................
About the IE-MediaChassis/2 (DC) The IE-MediaChassis/2 (DC) is a stand-alone chassis for use with iMcV modules. As an unmanaged chassis, the IE-MediaChassis/2 (DC) supports two single-wide or one dual-wide iMcV module. All iMcV modules, with the exception of the SNMP management card, will function properly in this chassis. The IE-MediaChassis/2 (DC) contains an internal Telco compatible DC power supply. The iMediaChassis/2 (DC) includes a temperature triggered fan.
3. If mounting the chassis on a wall, place two #10 panhead screws (not supplied) on the wall the distance of the holes on the chassis, and then hang the unit on the screws. 4. Attach the cables between the chassis and the device that will be interconnected, and then plug the unit into a reliable, filtered power source. Configuring and Installing Modules IMC Networks recommends turning the chassis power off before proceeding. 1.
DC Power Supply Wiring Instructions The following image shows the wiring configuration for a 48 VDC power supply in a negative ground system application. For positive ground system applications remove the chassis ground shorting jumper and connect it between the positive terminal and the chassis ground terminal. Alternatively, the chassis grounding jumper can be eliminated and the chassis ground connected at the power source. NOTE Incorrect wiring will result in chassis malfunction.
3. The DC supply source shall be located within the same premises as this equipment. 4. Switching or disconnecting devices shall not be in the grounded circuit conductor between the DC source and the point of connection of the grounding electrode conductor. Rackmount Precautions 1. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient.
DC Power Supply Precautions The following precautions must be observed when installing the chassis model with an internal DC power supply. 1. 2. Check nameplate ratings to ensure there is no overloading of supply circuits that could effect over current protection and supply wiring. In addition, the following must be observed: a. Connect the equipment to a 35 to 75 VDC power source that is electrically isolated from the alternating current source. b.
IMC Networks Technical Support Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); +32-16-550880 (Europe) Fax: (949) 465-3020 E-Mail: techsupport@imcnetworks.com Web: www.imcnetworks.com Specifications Environmental Operating Temperature: -31° F to 176° F (-35° C to 80° C) Storage Temperature: -67° F to 257° F (-55° C to 125° C) Humidity: 5 to 95% (non-condensing) DC Input Specification Input voltage: 35 to 75 VDC Input Current: 1.5A Output Current Capability: 15A @5 VDC Dimensions 2.23”H x 4.
Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to your add-in modules. Always observe the following precautions when installing or handling an add-in module or any board assembly. 1. Do not remove unit from its protective packaging until you’re ready to install it. 2. Wear an ESD wrist grounding strap before handling any module or component.
Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. CE: The products described herein comply with the Council Directive on Electromagnetic Compatibility (2004/108/EC) and the Council Directive on Electrical Equipment Designed for use within Certain Voltage Limits (2006/95/EC). Certified to Safety of Information Technology Equipment, Including Electrical Business Equipment. For further details, contact IMC Networks.
19772 Pauling • Foothill Ranch, CA 92610-2611 USA TEL: (949) 465-3000 • FAX: (949) 465-3020 www.imcnetworks.com © 2008 IMC Networks. All rights reserved. The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any errors that may appear in this document. IE-MediaChassis/2 is a trademark of IMC Networks. Other brands or product names may be trademarks and are the property of their respective companies.