User Manual
24
1. Turn off the power, remove the battery, and wait
at least 10 minutes for the ashtube to cool.
2. Remove the glass cover by gently pulling it off of
the ash head.
3. Using white cotton gloves or a clean cloth,
remove the retention wire wrapped around the
top of the ashtube.
4. With needle-nose pliers, unhook the retention
spring loop.
5. Once the spring is unhooked, grip the base of the
ashtube on each side, and carefully pull it from
the retaining sockets.
6. Apply rm, even pressure at the base of the
ashtube to gently push the pins of the new
ashtube into the sockets.
7. With needle-nose pliers, hook the retention spring over and above the
ashtube.
Note: This step can be done by hand. Make sure not to touch the ashtube
with your bare ngers.
8. Replace the glass cover.
Replacing the Flashtube