The Flash Tube
The Impact Digital Monolight’s ash tube is user-replaceable. To replace the
ash tube, do the following:
1. Discharge the ash unit by pressing the test button.
2. Power off the monolight and unplug the power cable from the ash unit
and power source.
3. After 30 minutes, remove the modeling lamp and any other accessory
connected to the unit.
4. Wearing a pair of cotton gloves or using a soft,
dry cloth and holding a pair of needle-nose pliers,
carefully unhook the retention spring loop of the
ash tube. Make sure it is disengaged from the
ash tube.
5. Once it is unhooked, grip the base of the ash
tube on each side and carefully pull it from the
monolight.
6. Pick up the new ashtube and push its pins into the sockets using rm,
even pressure at the base.
7. With needle-nose pliers, hook the retention spring over and above the
ash tube.
8. Reinsert the modeling lamp, then attach any accessory to the monolight.