User Manual

21
Note: The default setting of this function is t2, which means the ash will be triggered
after 2 seconds of preashes. When using multiple speedlites with different preash
frequencies, this mode will group all the ashes as one before ring.
To exit the Time Frame function menu, press and hold the slave button for
approximately 4 seconds until the ash power setting appears on the screen, or
slightly move the adjustment dial.
Block Time
The Block Time function allows for a variable of 1 to 18 milliseconds for the
studio ash to ignore master preashes. In this mode, your monolight will begin
to record and learn to recognize your device’s preashes. This is to compensate
for the different preash timing between devices. To use this function, refer to
the following instructions:
1. Press and hold the slave button for 8 seconds.
2. Press the slave button again.
3. Use the
or modeling light output buttons to select your required setting.
Use the following chart as a reference for this function’s settings:
Value (b) 1 2 3 4 5 6 7 8 9
Time (ms) 2 4 6 8 10 12 14 16 18
Note: The default setting on this mode is b5.
To exit the Block Time function menu, press and hold the slave button for
approximately 4 seconds until the ash power setting appears on the screen, or
slightly move the adjustment dial.