Impecca Window Air Conditioner Users Manual Model: IWA05-KR15 - 5000 BTU www.impecca.com v.0.
WARNING: To avoid permanent damage to unit: Ensure it is in the upright position for a MINIMUM of 6 hours and a RECOMMENDED time of 24 hours before powering on the first time. ADVERTENCIA: Para evitar daños permanentes a la unidad: Asegúrese de que está en la posición vertical durante un mínimo de 6 horas y un tiempo recomendado de 24 horas antes de encender la primera vez. Spanish version of this manual available for download on www.impecca.
Introduction...............................................................................................................................6 Getting To Know Your Air Conditioner...................................................................................7 Using Your Air Conditioner......................................................................................................7 Delay Start/Stop (Timer)................................................................................................
ENGLISH READ THESE NOTICES CAREFULLY—THEY ARE IMPORTANT! WARNING Plug in power plug completely. • Otherwise, it may cause electric shock or fire due to potential short circuit. Do not modify power cord length. • It may cause electric shock or fire. Always ensure effective grounding/ earthing. • Incorrect or missing grounding may lead to electric shock. Unplug the unit if it emits strange sounds, smells or smoke. • Unit may need repair.
Stop operation and remove unit from window in severe storm or hurricane. • Operation during a severe storm may allow a significant amount of water to enter the indoors. Do not place obstacles around air-intake vents or inside cool air outlet. • It may cause failure of appliance. Do not use strong detergent such as wax or paint thinner to clean the unit. Use a damp, soft cloth. • Appearance may deteriorate due to change of product color or scratching of its surface.
ENGLISH INTRODUCTION Thank you for purchasing this quality Impecca window air conditioner unit. To ensure the longest life and highest energy efficiency of your unit, please carefully follow these operating instructions. Keep these instructions in a safe place and consult them as needed.
• The air conditioner must be operated within the temperature range of 62°F to 95°F (16°C to 35°C). • A perimeter of 12′′(30cm) around the air conditioner should be free of all objects. • Keep air inlet and air outlet clean and free of obstructing objects. • During operation, close doors and windows to improve cooling effect. • Please put the air conditioner at smooth and flat ground for operation to avoid noise and vibration. • Do not tilt or turn over the air conditioner.
ENGLISH OVERVIEW OF CONTROLS AND FUNCTIONS Before you begin, thoroughly familiarize yourself with the control panels as shown below and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control panel located on the front of the device or with the remote controller. 1. Temperature/Timer Down 2. Timer (Delay start/stop) 3. Check Filter light reset 4. Function selector (Auto-Cool-Dry-Fan) B L C K 5. Energy Saver D J 6. On/Off 7.
Press or hold either Down or Up button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 62° F (17° C) and 86° F (30° C). If you want the display to read the actual room temperature, refer to the note: “To Operate on Fan Only”. FAN SPEED ADJUSTMENT Select the Fan Speed in four steps: Auto, Low, Med or High. Each time the button is pressed, the fan speed mode is shifted.
ENGLISH ENERGY SAVER MODE This function is available on COOL mode. The fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10-minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on and Cooling Starts. Note that due to modern energy saving regulations, this mode is on by default and you must turn it off if you want the fan to run constantly during cooling mode.
The timer buttons enable two separate functions: one to automatically start the unit within a 24 hour period of time and another to automatically turn off the unit within a 24 hour period of time. These functions are called, respectively, AUTO ON and AUTO OFF. AUTO ON INSTRUCTIONS: 1. Press the TIMER button twice, or until the TIMER ON LED on the air conditioner's control panel should illuminate. The air conditioner's display shows the last Auto-On setting (if any).
ENGLISH PRE-INSTALLATION INSTRUCTIONS REQUIRED TOOLS (NOT INCLUDED) Level Phillips Screwdriver Scissors Pencil Tape Measure INCLUDED PARTS & ACCESSORIES* 1. 2. 3. 4. Air conditioning unit Flexible window filler panels Upper Rail Upper Rail seal (may already be attached to bottom of rail) 5. Foam sash seal (no adhesive) 6. Foam seal (with adhesive) 7. Upper Rail Screws (x4) 8. ½” or ¾” Screws (x6) 9. Frame lock 10. Window security bracket 11.
Your air conditioner is designed to install in a standard double hung windows with opening widths of 23 to 36 inches (584mm to 914mm) and a height of 13 inches minimum.
ENGLISH INSTALLATION INSTRUCTIONS Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage. Note: Save original carton and these installation instructions for future reference.
Note: For safety reasons, all four (4) screws MUST be securely fastened. SIDE PANEL INSTALLATION NOTE: Top rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of the unit (5/16”). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained. 1. Place unit on the floor, a bench, or a table.
ENGLISH Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. Figure 4 Note: If storm window blocks AC, see Figure 13 2. Keep a firm grip on the air conditioner, and carefully place the unit into the window opening so that the bottom of the air conditioner frame is against the windowsill (See Fig. 5).
6. To secure lower sash in place, attach right angle sash lock with 3/4” (19mm) or ½” (13mm) screw as shown. (See Fig.11). 7. Cut foam seal and insert in the space between the upper and lower sashes (See Fig. 12) REMOVING AC FROM WINDOW • • • • • Turn AC off and disconnect power cord. Remove sash seal from between windows and unscrew safety lock. Remove screws installed through frame and frame lock. Close (slide) side panels into frame.
ENGLISH CLEANING & MAINTENANCE SAFETY WARNING To avoid electric shock, fire, damage, or injury while performing maintenance on your unit: • Always turn off and disconnect the air conditioner from electric power. • Never submerge the unit in water or spray liquids directly on the unit. • Never use solvents or other flammable or volatile liquids (examples: paint thinner, acetone, gasoline, etc.) to clean the air conditioner.
If dust has accumulated on the unit, use a soft, dry dusting cloth to wipe it off. If grease or other harder to remove substances is on the unit, use a wrung-out cloth dampened with warm, soapy water. Use a soft brush to clean off the grille. CLEANING THE FILTER For energy efficient operation, your filter should be cleaned at least once a month. Units in dusty environments may require more frequent filter cleaning. • The filter simply slides out the right side of your unit.
ENGLISH WATER BUILD-UP IN THE UNIT, SPLASHING NOISE • This is not a problem. This self-evaporative unit is designed allow condensate to build up in the rear of the unit during cooling and dry modes. The rear fan then runs through the pool of water, splashing it upon the evaporator coils, helping to cool them down. This makes the unit more efficient and eliminates the need to hook up a drain hose. THE AIR CONDITIONER UNIT STARTS AND STOPS VERY FREQUENTLY.
• • • • • • 115 Volts, 60Hz, 1Ph Watts (Rated): 446 Amps (Rated) 4 Power cord length: 6.5’ EER: 11.1 Plug Face: 5-15P 5-15P CUSTOMER SUPPORT Before contacting customer support, please see the troubleshooting guide above. Upon unpacking your air conditioner, please be sure to write down the model and serial number of your unit. This will be needed should your unit require servicing in the future.
ENGLISH ONE-YEAR LIMITED APPLIANCE WARRANTY (US) Impecca™ warrants this product against defects in material and workmanship to the original purchaser as specified below. ESPAÑOL PARTS AND LABOR– if the product is determined to have a manufacturing defect, within a period of one year from the date of the original purchase, Impecca™, at its own discretion, will repair or replace the product parts at no charge to you in the U.S.A.
PARTES Y MANO DE OBRA– Si se determina que el producto tiene defectos de fabricación, dentro del periodo de un (1) año a partir de la fecha de compra original, Impecca™, a su discreción, reparará o reemplazara las partes del producto sin ningún costo para usted en los Estados Unidos. Para obtener el servicio de garantía de un distribuidor autorizado de Impecca™ envíenos un correo electrónico a: service@ impecca.
ENGLISH GARANTIE LIMITÉE D’UN AN (US) Impecca™ garantie auprès de l’acheteur original cet appareil contre toutes défectuosités liées au matériel et à la fabrica- ESPAÑOL tion tel que spécifié ci-dessous. FRANÇAIS PIÈCES ET MAIN D’ŒUVRE- S’il est déterminé que l’appareil a un problème lié à la fabrication, à l’intérieur d’une période d’un an de la date d’achat originale, Impecca™, à sa discrétion, pourra remplacer ou réparer les pièces de l’appareil sans frais pour vous aux États-Unis.