Through-The-Wall Air Ai Conditioner User Manual Models: ITAC08-LSA23 ITAC10-LSA23, ITAC10-LSB24 ITAC12-LSA23, ITAC12-LSB24 ITAC14-LRB24 www.impecca.com v. 0.
INTRODUCTION IMPORTANT SAFETY INSTRUCTION ...........................................................................1 ELECTRICAL REQUIREMENTS ................................................................................... 2 INTRODUCTION TO REFRIGERANTS R32 ...................................................................3 PACKING LIST ............................................................................................................5 INSTALLATION & ASSEMBLY INSTRUCTIONS .....................
1
8K/10K/12K-115V Cooling 2 8K/10K/12K/14K Cooling & Heating 10K/12K/14K-230V Cooling
INTRODUCTION TO REFRIGERANTS R32 The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of erant is combustible and odorless. Moreover, it can burn and explode under certain condition. However, there will be no risk of burning and explosion if you comply with the following table to install your air conditioner in a room with an appropriate area and use it correctly.
1. Site Safety Open Flames Prohibited Mind Static Electricity Open Flames Prohibited Ventilation Necessary Must Wear Protective Clothing and anti-static gloves Don't use mobile phone 3. Installation Safety Refrigerant Leak Detector Appropriate Installation Location The left picture is the schematic diagram of a refrigerant leak detector Please note: The installation site should be in a well-ventilated condition.
IMAGE PAPT QUANTITY Through-The-Wall Air Conditioner 1 Remote Controll 1 Trim Frame 1 (Left&Right legs) 2 Trim Frame 2 (Top&Bottom legs) 2 Grille Aluminum 1 Rear plastic net 1 1/2" Long Hex-head Screw 4 Grouding wire with tooth washer 1 Battery 2 Dimension PAPT QUANTITY 1’’x3/4’’x14’’ Seal sponge 2 1’’x3/8’’x14’’ Seal sponge 2 1’’x3/8’’x25’’ Seal sponge 3 1’’x1 1/2’’x25’’ Seal sponge 3 1’’x1 1/2’’x14’’ Seal sponge 2 1’’x1 1/2’’x84’’ Seal sponge 1 3 3/4’’x1 1/2’’x4’’
Condition1: Install the back grille to the Wall-sleeve (Prior Suggestion) 1, Identify the wall-sleeve brand for your preparing, from the below chart. Type Standard Dimension Wall-sleeve Dimensions Height 15 Depth Width 4’’ 25 ’’ ’’ ’’ NOTE a, All wall sleeves used to mount the new air conditioner must be in sound structural condition and have a rear grille that securely attached to the sleeve, or rear flange that serves as a stop for the air conditioner.
6, Install the grounding wire. a, Install screw end of ground wire into inside of sleeve according to preparation instruction. b, Remove the second screw from left side of unit, and remove the screw plastic washer. c, Screw the other end of the ground wire into the unit. Make sure the toothed washer is against the cabinet. 4, Install the Seal. (1) Stick 1’’x4/5’’x13 4/5’’ sponges to the condenser side plate, for both left and right at the back side of TTW unit. (2) Seal the Wall-sleeve inside.
c, Be sure that, from the back side of the TTW, the seven inlet opening should be at left, and the eight inlet opening should be at right. Trim Kit Installation Instructions 1. Install the 1''x1 1/2'' x84'' long stuffer seal between the wall sleeve and the unit. A flat-bladed screwdriver or putty knife is needed. 2. Assemble the trim frame by inserting the top and bottom pieces into side pieces and snapping into place. 3.
1 For Cooling model WIFI Symbol* Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces air humidity. Press the MODE button to activate the cooling function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated. Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press MODE button to set the DRY mode.
10. Directional Louvers: To direct the airflow, use the 6. ECO Button: When the unit is in ECO mode, the horizontal wheel to control the horizontal direction light will turn on. In ECO mode, the unit will turn-off and the air deflector to control the vertical once the room is cooled to the user set temperature. direction. The unit will turn back on when the room temperature rises above the user set temperature.
1 5. Timer: Use these buttons on the control panel and remote to set the Timer. Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button or until the rest time displayed is to your demand then press TIMER button again. Timer On: When the unit is off, press TIMER button at the first time, set the temperature with pressing the button or . Press TIMER button at the second time, set the rest time with pressing the button or .
FIG.21 FIG.
13
Display dr and unit without control The air conditioner is under demand response, only turn ON/OFF can be actived, and the set temperature may raise, and the compressor may stop. 14 It is the demand response condition, you can wait for the Delay time or override it by long press down button for 3s on the control panel.
COSTUMER SUPPORT Before contacting customer support, please see the troubleshooting guide above. Upon unpacking your air conditioner, please be sure to write down the model and serial number of your unit. This will be needed should your unit require servicing in the future. The number is found on a barcode on the right side of the air conditioner and on a similar barcode on the outside of the box the unit came in.
ONE-YEAR LIMITED APPLIANCE WARRANTY (US) Impecca™ warrants this product against defects in material and workmanship to the original purchaser as specified below. PARTS AND LABOR– if the product is determined to have a manufacturing defect, within a period of one year from the date of the original purchase, Impecca™, at its own discretion, will repair or replace the product parts at no charge to you in the U.S.A.