Installation Sheet

Imperial Cal Products, Inc.
Read Before Starting Installation!
Inspect your range hood prior to installing!
Any cosmetic defects must be reported to us prior to installation.
Once this hood is installed, ICP will NOT accept any responsibility
for any cosmetic blemishes, scratches or dents in the Canopy.
Save all original packaging if you wish to return for any reason!
FIRST:
Check your local building and electrical codes.
WARNING:
To reduce the risk of fire or electrical shock, Do Not use any two speed motor units with a Solid State
control devise.
CAUTION:
To reduce the risk of fire or personal injury and to properly exhaust air, be sure to duct air to the outside.
DO NOT vent exhaust air into spaces within wall, attics, ceilings, crawl spaces or garages. When venting
to the outside make duct run as short and straight as possible. Avoid using elbows if at all possible. If
elbows are used, we recommend that the first elbow is 24” from vent opening on the hood (minimum of 6”)
and at least 24” between it and the next elbow. We strongly recommend no more then two 90 degree
elbows in any duct run. No Performance Warranty when used above BBQ Style Grills.
DO NOT use duct pipe smaller than the outlet duct opening on the hood, this will reduce performance and
void the warranty. DO NOT use flex ducting. Also, use either a Roof Cap or Wall Cap to end run. Be
sure that all joints are taped securely in place.
It is essential to have the proper distance between the bottom of the range hood and the cooking surface
below. In most cases the cooking appliance manufacturers specifications will establish the fire safe
minimum distance required, although there are other factors to consider:
! Local Building Codes
! Cross directional air movements ie: open windows, air conditioning/heating outlets, cooling fans, etc.
! Overall size of the cooking appliance and surrounding countertop surfaces.
! Range hood model selected.
Minimum distance between cooking surface and the bottom of the hood is 30” and 36” is the maximum
distance. Keep in mind, increasing the distance will decrease the performance.
TWIN UNITS ONLY - Transitioning two pipes into one is NOT recommended. CFMs are reduced by
25% and the Performance warranty will be void.
PROPERTY OF HOME OWNER, DO NOT THROW AWAY!