Installation Instruction

Wall Mount Installation Detail:
4. Bring conduit down and feed through 7/8” hole on
top of the canopy, at least 18” to 24” long. Be sure
that the conduit hangs 4” past the bottom of the
canopy. Remove junction box cover from the
C2000. BP1 does not have C2000, junction box is
on the inside top of unit. (Be sure to comply with all
local electrical and safety codes) Remove Black
Tape that holds the Damper Blades in closed
position. *It is NOT recommended to use 2
dampers during installation. You have the
option to put a external damper or use the
existing damper already on the unit.
5. Attach special length of vent pipe to the vent
opening on the C2000 (using Automatic Vent
Collar) to extend through opening in the top of the
canopy.
6. Position the C2000 (with vent pipe in the Collar)
into the canopy, with support bolts through the
holes in the top of the C2000. Secure washers and
nuts on all weld Studs, tighten securely.
7. Hook up electrical wires and secure electrical
cover.
8. Replace filters. For Baffle Filters, in stall grease
tray towards the back of liner. Take one baffle,
slide between steel strips towards the front of the
liner and push back into grease tray grooves, then
slide to one side. Insert second baffle the same
way and slide to opposite side. (Grease holes, on
bottom of baffle must be inserted into grease tray)
Take Center Panel and slide in towards the front of
the liner and push back into grease tray.
9. Duct Cover - Peel brown tape on brackets located on top of
range hood. Line up duct cover to brackets and press
against brackets. You can caulk back flanges to wall if
you desire, but it’s not necessary.
TWIN UNITS ONLY
Transitioning two pipes into one is NOT recommended. CFMs
are reduced by 25% and the Performance warranty will be void.
*WHP1936PSSB & WHP1900BP1—Come with Slim Baffle Filters only.
Units are to be hard wired
. It is not recommended to add a power-cord. Adding a
power cord can loosen existing wires inside junction box causing electrical
failure.
Black Tape on Damper
WH1900PSB
WH1900PS1-TWB
WHP1900PSB
WHP1900PS1-TWB
BP1 does not have C2000 Liner. Junction box is
on the inside top of unit.
BP1 Includes: 10-1/4”-3-1/2” rectangle to 7” round
transition with adapter piece. If you have
rectangular piping, no need to use transition piece.
WHP1900BP1