Installation Sheet

Wall Mount Installation Detail:
MODELS: MODELS:
WH2000PSSB WH2000PS1-TWSB
WHN2000PSSB WHN2000PS1-TWSB
WHN2000BPSB WHN2000BP1SB
CAUTION: Be sure that incoming power is turned off.
1. Locate height of range hood.
2. From bottom of hood, measure 6” up and draw a line.
3. Take “U” shape installation bracket and line the bottom of the bracket up with the
line (center bracket left to right) install bracket using #10 x 2-1/2” wood screws, if
you have wood to screw in to. If not use the 3/16” x 3” toggle bolts.
4. Lift up hood and connect hood brackets to installation bracket using (8) 10-32
Hex Keps nuts and (8) 10-32 x 3/4 screws. Make sure hood is level before you
tighten all screws.
5. Use (2) 3/16” x 3” toggle bolts or #10 x 2-1/2” wood screws and (2) 1-1/4” OD
Fender washers to secure to back of wall.
6. Bring wires down and feed through 7/8” hole on top of the hood, at least 8” to 10”
long.
7. Remove junction box. (Be sure to comply with all local electrical and safety
codes) Remove Black Tape that holds the Damper Blades in closed position.
Attach special length of vent pipe to the vent opening on top of
hood. *It is NOT recommended to use 2 dampers during in-
stallation. You have the option to put a external damper or
use the existing damper already on the unit.
Duct Sizes Indicated in Model # (Ex: WH2048PSSB-K)
** - 8
= 8” DUCT PIPE
** - K
=10” DUCT PIPE
If not indicated by an 8 or a K, duct pipe is 7” Round.
Refer to #5
Brackets
Top
Black Tape on Damper