Installation Sheet
Wall Mount Installation Detail:
8. Hook up electrical wires and secure electrical cover.
9. Replace filters. For Baffle Filters, install grease tray towards the back of liner. Take
one baffle, slide between steel strips towards the front of the liner and push back into
grease tray grooves, then slide to one side. Insert second baffle the same way and
slide to opposite side. (Grease holes, on bottom of baffle must be inserted into
grease tray) Take Center Panel and slide in towards the front of the liner and push
back into grease tray.
10. Install duct cover by peeling back brown tape on the brackets located on the top of the
range hood. Line up duct cover to brackets and press firmly. You can using caulking
on the back flanges if you wish, but it’s not necessary.
TWIN UNITS ONLY—Transitioning two pipes into one is NOT
recommended. CFMs are reduced by 25% and the Performance warranty will be void.
WH2000PSSB
WH2000PS1-TWSB
WHN2000BP1SB WHN2048BPSB
WHN2000PSSB
WHN2000PS1-TWSB