user manual

Power Consumption in ES
Mode - Suspend to RAM
(S3) (Instantly Available
PC)
<3W <3W
High voltage immunity
up to 410V/s
N/A
China Telecom YD/T 993-
2006 spec
Yes
N/A
System Environmental
System EnvironmentalSystem Environmental
System Environmental
Specs
SpecsSpecs
Specs
Values are subject to change without notification and are for reference only.
Performance of system, options, and ancillary equipment will vary depending on the system
configuration.
Levels presented do not account for non-HP/Compaq installed hardware.
Ambient Air Temperature
Ambient Air TemperatureAmbient Air Temperature
Ambient Air Temperature
Operating
OperatingOperating
Operating
MT: Operating 41° to 95°F (5 to 35°C) (Test 0 to
104°F (40°C));
SFF: 50° to 95°F (10° to 35°C) at sea level with
an altitude de-rating of 1.0°C per every 1000 ft
(300 m) above sea level to a maximum of
10000 ft (3048 m), no direct sustained sunlight.
Maximum rate of change is 50°F/Hr (10°C/Hr).
The upper limit may be limited by the type and
number of options installed.
Storage
StorageStorage
Storage
MT: Storage: 90% RH @ 60°C for 12 hours
(Non-condensing)
SFF: –22° to 140°F (–30° to 60°C).
Humidity
HumidityHumidity
Humidity
Operating
OperatingOperating
Operating
MT: 10% to 90% relative humidity (Rh), 35°C
non-condensing
SFF: 10% to 90% relative humidity (Rh), 35°C
maximum wet bulb temperature, non-condensing
Storage
StorageStorage
Storage
MT: 90% relative humidity (Rh), 60°C for
12 hours, non-condensing
SFF: 90% relative humidity (Rh), 60°C for
12 hours, non-condensing
Altitude
AltitudeAltitude
Altitude
Operating
OperatingOperating
Operating
MT: 0 to 10,000 feet (0 to 3048 meters) – This
value may be limited by the type and number of
options installed.
SFF: 0 to 10,000 feet (0 to 3048 meters) – This
value may be limited by the type and number of
options installed. Maximum allowable altitude
change rate is 1,000 ft/min (304.8 m/min).
Non-Operating
Non-OperatingNon-Operating
Non-Operating
MT: 0 to 30,000 feet (0 to 9,144 meters)
SFF: 0 to 30,000 feet (0 to 9,144 meters) –
Maximum allowable altitude change rate is 1200
ft/min (365.76 m/min).
Shock
ShockShock
Shock
Listed are the levels of vibration the product can withstand with No damage
being incurred. The values represent a flat random vibration input
acceleration profile across the given frequency range.
Non-Operating
Non-OperatingNon-Operating
Non-Operating
35G's (Half-sine Shock)
30G's (Trapezoidal Shock)
QuickSpecs
HP Pro 3010 Business PC
HP Pro 3010 Business PCHP Pro 3010 Business PC
HP Pro 3010 Business PC
System Details
DA - 13491 Worldwide — Version 1 — November 5, 2009