User's Manual
Copyright © 2019 InCoax Networks AB. All rights reserved. 11
Confidential under NDA
6 Specifications
6.1 in:xtnd™ Control C251
The electrical, physical and functional specifications for the in:xtnd™ Control C251. Please note that the
specification may be subject to change.
Performance • Based on MoCA Access 2.5 Profile D. See reference {a}.
• 10 Gbps WAN interface.
• 2.5 Gbps throughput for the MoCA port. (3.0 Gbps in turbo mode.)
• 31 Modems for port.
• MoCA Bands: A - A, A - B, A - C, A - D, and A - E.
• Frequency range: 400 to 1675 MHz.
• RF channel bandwidth: 100 MHz.
• Bonded operation supporting 3, 4, or 5 RF channels.
• MAC Rate typically 1.5, 2.0, or 2.5 Gbps (up to 3.0 Gbps).
• PHY / MAC rate: up to 730 / 600 Mbps per 100 MHz RF channel.
• 100 % link quality up to 60 dB attenuation.
• 17 dBm maximum output power; automatically adjusted per modem.
• Configurable beacon frequency.
• Modulation: OFDM, QAM 8, 16, 32, 64, 128, 256, 512, or 1024; BPSK and QPSK.
• Multiplexing methods: TDMA/TDD.
Physical: • Northbound fiber port.
• 1 × SFP+ port: Multi Source Agreement (MSA) compliant, SerDes – 10 Gbps data rate,
SFF-8472 (see reference {h}) – Diagnostics interface.
a
• 1 × Management Ethernet port: 10 / 100 Mbps, configuration and statistics port.
• RJ-45 connector supports type CAT5 UTP (as a minimum).
• F-female connector - 3/8-UNEF32, 75 Ω.
• Reset button for executing system reset and enter a default state.
Indicators • Power on, Management, Trunk, Coax Link traffic, and alerts.
Dimensions • 323 × 57 × 194 mm (W × H × D).
• Prepared for 19” rack chassis installation.
• Prepared for wall mount.
Weight • 3.2 kg
Environmental • Operating temperature: -25 °C to +50 °C.
• Relative humidity: 20 % to 80 %.
• Altitude: maximum 2000 m.
• Dynamic temperature control with cooling redundancy.
• Abnormal operation conditions alarms.
• Storage (non-condensing): -40 °C to +70 °C and 5 % to 90 % relative humidity.
• RoHS and RoHS2. See reference {c}.
• UL 94 V-0. See reference {i}.
Power • 12 VDC, 5 A nominal.
• Power consumption is 17 W nominal.
• Automatic power on after power grid failure.
a
InCoax recommends using the SFP+ module “MikroTik 10G S+RJ10”.
Other SFP+ modules that are tested:
Ubiquiti 10G UDC-2;
Fiber MM: Ubiquiti 10G UF-CoaxMM-10G;
Fiber SM: Ubiquiti 10G UF-SM-10G, In 10G OS-SP96-3110D, Ubiquiti Bi-Di UF-SM-10G-S.
Kommenterad [CL5]: Stämmer dessa?