! Please keep this instruction booklet in a safe place for
future reference.. Make sure the booklet remains with the
appliance if it is sold, given away or moved.
! Please read this manual carefully: it contains important
information on installation, operation and safety.
! The appliance must be installed by a quali ed professional
in accordance with the instructions provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected from
the electricity supply.
Positioning and levelling
! The appliance may be installed alongside any cupboards
whose height does not exceed that of the hob surface.
! Make sure that the wall which is in contact with the back
of the appliance is made from a non- ammable, heat-
resistant material (T 90°C).
To install the appliance correctly:
Place it in the kitchen, the dining room or the studio  at
(not in the bathroom).
If the top of the hob is higher than the cupboards, the
appliance must be installed at least 600 mm away from
them.
If the cooker is installed underneath a wall cabinet, there
must be a minimum distance of 420 mm between this
cabinet and the top of the hob.
This distance should be increased to 700 mm if the wall
cabinets are  ammable (see  gure).
Do not position blinds behind the cooker or less than
200 mm away from its
sides.
Any hoods must be
installed in accordance
with the instructions listed
in the relevant operating
manual.
Levelling
If it is necessary to level the
appliance, screw the adjustable
feet into the positions provided
on each corner of the base of the
cooker (see  gure).
The legs*  t into the slots on the
underside of the base of the cooker.
Electrical
connection
Fitting the power supply
cable
To open the terminal
board:
Insert a screwdriver
into the side tabs of the
terminal board cover.
Pull the cover to open it.
To install the cable, follow the instructions below:
Loosen the cable clamp screw and the wire contact
screws.
! The jumpers are pre-set at the Factory for 230 V single-
phase connection (see  gure).
NL
230V ~
H05RR-F 3x4 CEI-UNEL 35363
1
3
2
4
5
H05VV-F 3x4 CEI-UNEL 35746
To carry out the electrical connections as shown in the
gures, use the two jumpers inside the box (see  gure -
labelled “P”).
N
L2
L1
L3
P
Installation
HOOD
420
Min.
min.
650
mm. with hood
min.
700
mm. without hood
mm.
600
Min. mm.
420
Min. mm.