Instruction for Use

8
GB
Supply pressures Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Rapid (R)
Reduced Rapid (RR)
Semi Rapid(S)
Auxiliary (A)
Triple Crown (TC)
100
100
75
55
130
0.70
0.70
0.40
0.40
1.50
3.00
2.60
1.65
1.00
3.30
39
39
28
28
61
86
80
64
50
65x2
218
189
120
73
240
214
186
118
71
236
3.00
2.60
1.65
1.00
3.30
132(H)
122(H)
96(Z)
79(6)
103x2
286
248
157
95
343
Burner and nozzle specifications
* At 15°C and 1013,25 mbar - dry gas
** Propane P. C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m³
Thermal
power kW
(p.c.s.*)
Reduced
Thermal
power kW
(p.c.s.*)
Nominal
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Flow*
(g/h)
Flow*
(l/h)
Diameter
(mm)
Table 1 Liquid Gas Natural Gas
Burner Thermal
power kW
(p.c.s.*)
Nominal
Nozzle
1/100
(mm)
*** **
PC 640 X/HA TK
R
S
A
PC 640 T X/HA TK
RR
TC
S
A
S