Instruction for Use

GB
14
Fastening hooks are provided, allowing you to
fasten the hob to tops that are between 20 and 40
mm thick. To ensure the hob is securely fastened to
the top, we recommend you use all the hooks
provided.
555 mm
55 mm
475 mm
Hook fastening diagram
20
30
Hooking position Hooking position
for top H=20 mm for top H=30 mm
Front
40
Hooking position Back
for top H=40 mm
Use the hooks contained in the accessory pack
Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This
must be placed at a minimum distance of 20 mm
from the lower part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the
cabinet must be removed. It is advisable to install the
oven so that it rests on two strips of wood, or on a
completely flat surface with an opening of at least 45 x
560 mm (see diagrams).
Where a hob is installed above an oven without a
forced ventilation cooling system, adequate ventilation
must be provided inside the cabinet by means of air
holes through which air can pass (see figure).
Electrical connection
Hobs equipped with a three-pole power supply cable
are designed to operate with alternating current at the
voltage and frequency indicated on the data plate
(this is located on the lower part of the appliance). The
earth wire in the cable has a green and yellow cover.
If the appliance is to be installed above a built-in
electric oven, the electrical connection of the hob and
the oven must be carried out separately, both for
electrical safety purposes and to make extracting the
oven easier.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load
indicated on the data plate.
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum
contact opening of 3 mm installed between the
appliance and the mains. The circuit-breaker must be
suitable for the charge indicated and must comply with
current electrical regulations (the earthing wire must not
be interrupted by the circuit-breaker). The supply cable
must not come into contact with surfaces with
temperatures higher than 50°C.
The installer must ensure that the correct electrical
connection has been made and that it is compliant
with safety regulations.
Before connecting to the power supply, make sure
that:
560 m
m
.
4
5 m
m
.