Operation Manual

GB
7
NATURAL GAS
(Methane)
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
Model configuration
5 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m³) for
burning1m³ of gas
Rapid
Semi-Rapid
Auxiliary
MW
G20
115Y
95Z
72X
138A
85
63
50
91
Burner and nozzle specifications
Table 1
TYPE OF GAS
USED
TYPE OF
BURNER
NOZZLE RATED
THERMAL
FLOW RATE
kW
RATED
CONSUMPTION
REDUCED
HEAT
CAPACITY
kW
GAS PRESSURE
mbar
min. rat. max.
3.00
1.65
1.00
3.50
3.00
1.65
1.00
3.50
286 l/h
157 l/h
95 l/h
333 l/h
218 g/h
120 g/h
73 g/h
254 g/h
0.75
0.40
0.40
1.65
0.75
0.40
0.40
1.65
G20 20 mbar 1MW -1R - 2S -1A 10.80 1028 l/h 9.52
G30 28-30 mbar 1MW -1R - 2S -1A 10.80 785 g/h 30.94
Type of gas used
ELECTRIC SUPPLY: 220-240V~ 50/60Hz 0,6W
CATEGORY II2H3+
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
85
63
50
91
3.00
1.65
1.00
3.50
214 g/h
118 g/h
71 g/h
250 g/h
0.75
0.40
0.40
1.65
25 37 45
G31 37 mbar 1MW -1R - 2S -1A 10.80 771 g/h 23.80
Rapid
Semi-Rapid
Auxiliary
MW
Rapid
Semi-Rapid
Auxiliary
MW
20 28-30 35
A
MW
R
S
S
THP 751 W/IX/I