# 3 Weigh-in / Weigh-out
This program uses the ID memory for weigh-in / weigh-out transactions. An ID
record is created using the Weigh-in function. The Weigh-out function recalls the
ID, calculates Gross/Tare/Net of the transaction, prints the transaction, and adds
the net weight to the ID’s totals register. The ID data is saved for further weigh-
in/weigh-out transactions, or weigh-out only transactions. A sequential
transaction number is maintained for printing purposes.
Weigh-In
Press the F1 key. The display prompts "id". Enter up to 8 digits for the weigh-in
ID and then press the ENTER key. The scale weight is stored in the ID's tare
register and print page 3 is sent to the printer. If the ID has been weighed in but
not weighed-out then "Err 20" is displayed. Press the CLEAR key to exit without
changing the ID data, press the ENTER key to enter the new ID data.
Weigh-Out
Press the F2 key. The display prompts "id". Enter up to 8 digits for the weigh-out
ID and then press the ENTER key. The indicator recalls the ID from memory,
calculates the gross, tare and net weights, totals the net weight and sends the
weigh-out data (page 2) to the printer. If an ID is entered that is not found in
memory the displays "Err 21". Press the CLEAR key to exit the weigh-out
function.
The print formats label “(IN) GROSS” for weigh-in gross transactions, “(IN)
TARE” for weigh-in tare transactions, and “MEM TARE” to designate Memory
tare for ID’s recalled 2 or more times.
Print ID’s, Display ID’s, Clear Totals, Erase ID’s
Entering ID 0 accesses the ID maintenance functions. Press the F1 (or F2) key,
press the numeric 0 key, and then press the ENTER key. The display prompts
"rePort". Press the UNITS () key or the PRINT () key to scroll through the ID
file maintenance menu.
REPORT: Press the ENTER key when the display prompts "rePort". The
display then prompts "id". Enter an ID number to be printed or enter the numeric
0 to print all ID's and depress the enter key and report will be printed on port 1.
DISPLAY ID’s: Press the ENTER key when the display prompts “diSPLA”. The
display then prompts “id”. Enter an ID number to display the data in its registers,
or enter 0 and then the ENTER key to scan ID memory.
CLEAR TOTALS: Press the ENTER key when "CLEAr" is displayed. The
display prompts "id". Enter an ID number to clear or enter the numeric 0 to clear
all ID totals and depress the ENTER key.
ERASE ID'S: Press the ENTER key when the display prompts "ErASE". The
display then prompts "id". Enter an ID to be erased or enter the numeric 0 to
erase all ID's and depress the ENTER key.