Instruction Manual

IDS 430/433 Users Manual Version 1.0
- 37 -
Parameter 27 TX2 Control / Station ID (255 [single station])
Serial Port 2 can be used for continuous transmission of scale data or as a
network buss or for single station remote control.
Enter a 0 to enable continuous transmission of TX 2 data. The data sent is
configured in parameter 28 (TX2 Format).
Enter a station ID (1 to 254) for multi-drop network configuration
Enter 255 for single station remote control
Parameter 28 TX2 Format (2 Condec format)
Serial Port 2 can be used for continuous transmission of scale data. The TX2
Format parameter determines what is sent. There are 5 selections:
1 - AND: <status>, <mode>, <polarity><weight><units><terminate>
Status: OL (overload), ST (stable), US (unstable, in motion)
Mode: GS (gross mode), NT (net mode)
Polarity: + (positive weight), - (negative weight)
Weight: 7 characters data, NOT zero blanked, with decimal point
Units: lb, kg, t (ton), tn (tonne), g<sp> (gram), oz
Terminate: lf, cr (line feed, carriage return)
2 - CONDEC: <stx><polarity><weight><units><mode>>status><terminate>
Polarity: space (positive weight), - (negative weight)
Weight: 7 characters, zero blanked, with decimal point
Units: L (lb), K (kg), T (ton), G (gram), O (oz)
Mode: G (gross mode), N (net mode)
Status: <space> (valid weight), M (motion), O (over wt), I(invalid)
Terminate: lf, cr (line feed, carriage return)
3 - WEIGHTRONIX: <mode1><mode2><polarity><weight><space><units><term>
Mode1: space (gross mode), 0 (zero if net mode)
Mode2: G (gross mode), N (net mode)
Polarity: + (positive weight), - (negative weight)
Weight: 6 characters, NOT zero blanked, with decimal point
Units: lb, kg, oz, g <space>(gram), t<space> (ton), tn (tonne)
Terminate: lf, cr (line feed, carriage return)
4 - OHAS:
<polarity><weight><space><units><2 spaces><mode><status><term>
Polarity: space (positive weight), - (negative weight)
Weight: 7 digits, zero blanked, with decimal point
Units: lb, kg, oz, g <space>(gram), t<space> (ton), tn (tonne)
Mode: G (gross mode), N (net mode)
Status: <space> (valid weight), M (motion), O (over wt), I(invalid)
Terminate: lf, cr (line feed, carriage return)
5 - Print label 85: transmits the contents of parameter 85 (print label 85)
Data entered into a print label can include register data:
[253] [reg no] buffer register data, minimum size (zero blanked no
spaces)
[254] [reg no] buffer data, 7 character field, zero blanked, right
justified.