Instruction Manual

IDS 430/433 Users Manual Version 1.0
- 62 -
Error Messages
Error Description
Err 0 Power on zero error. See parameter 20.
Err 1 Keyboard error. Occurs during power up while a key on the keyboard is being
pressed or one of the remote switch inputs is activated.
Err 2 Restart Trap. The microprocessor accessed nonexistent memory location. Usual
cause is A/C power “glitch” or static electric discharge.
Err 3 Watchdog Time-out. The weight display has not been updated within the watchdog
time-out period. Usual cause is A/C power glitch or static electric discharge.
Err 4 Battery Error. Battery voltage level was below 2 V when the IDS 430/433 was
powered off.
Err 5 Earom memory error. A checksum error has occurred when reading the
configuration earom memory. Check calibration parameters and rewrite the earom
memory. If error continues, replace earom (U12)
Err 5.1 Earom Time-out, unable to write to the earom memory.
Err 6 Ram memory error. A ram memory error has occurred. Replace U5 if error
continues.
Err 7 The A/D converter is “locked up”. Check load cell wiring.
Err 8 Negative deadload error.
Err 9 Count-by error. The entered value is outside the scale count-by set during
calibration.
Err 10 Pushbutton ZERO error.
Err 11 A to D converter not working.
Err 12 Negative deadload. Check loadcell wiring. Enter a deadload offset in configuration
parameter 19.
Err 14 Page Format line length error. The page format output exceeded the maximum
line length.
Err 15 The function selected is locked. Switch 1 (SW1) on the IDS 430/433’s circuit board
locks and unlocks configuration parameters.
Err 16 Scale Basic Stack Overflow.
Err 18 Referenced an invalid function instruction.
Err 21 ID not found.
Err 22 Scale Basic Prompt error.
Err 23 ID memory full.
Error OL
Calibration error or scale is over-loaded (above scale capacity).
undEr Calibration error or scale is under-loaded (below readable weight).