DT220 Users Manual version 1.a  Configuration Parameters 
    14 
Configure Parameters 
Press the Shift key and then the CFG/Test key (Function Key 9) to access the 
Configuration Parameters. The following menu is displayed: 
1  Scale Parameters 
2  Calibrate 
3  Com & Printer Ports 
4  Event Monitor 
5  ID Database 
6  PagePrinter 
7  Registers 
8  Meter Select 
9  Passwords 
10 System Initialize 
Use the Review and Cont. keys or the numeric keypad to move the pointer to a 
configuration menu item and then press the Enter key. 
Press the Clear Entry key to exit configuration mode. The display prompts: 
  Press P to program changes into ROM 
  Press X to discard changes 
Press P or X to save or discard changes. 
Scale Parameters 
The scale parameters configure DT220 for the weigh platform or load cell that it is 
connected to. 
1 A/D speed xxx Filter xx 
  2 Full Scale xxxxxx 
  3 Overload Wt xxxxxx 
  4 Count by: xxxx Alt: xxxx 
  5 Units Pri: uuuu Alt: uuuu 
  6 Zero xxx% delay xx band xx 
  7 Motion delay xx band xx blanks=y/n 
  8 P.O. Zero = Y 
Some of the following parameters are entered in terms of “graduations”. The full-scale 
graduations can be found by dividing the full-scale weight by the count-by weight. For 
example, if the scale is configured for 500.00lb x 0.05lb, the full-scale graduations is 
500.00/0.05 = 10,000 graduations to full scale. 
The numbers in parenthesis are the default factory settings. 
Note: Jumper TB3 pin 7 to TB6 pin 7 (Function Lock Jumper) to enable scale 
configuration and calibration. Jumper enabled as default from the factory RED wire. 
Remove to lock configuration after calibration. 