Scale Parameter 1.1: A/D speed (120 samples/second) 
The (optional) A/D “Load Cell Module” can operate at speeds from 30 samples/second to 
960 samples/second. The default of 120 samples/second bi-polar is optimal for most 
applications. Speeds of 480 and 960 are for special applications only (consult factory). 
Scale Parameter 1.2: Digital Filter (12) 
The digital filter removes scale vibrations and other noise signals from the weight 
display. The filter range is between 0 and 20. A setting of 0 provides no filtering; a 
setting of 20 provides maximum filtering. The higher the filter number, the longer the 
settle time of the weight display. For example: 
Filter Setting  Settle Time @ 120s/s
3  0.3 sec 
6  0.6 sec 
9  1.2 sec 
12  2.5 sec 
15  5.0 sec 
Use the smallest filter setting that provides satisfactory display stability. 
Scale Parameter 2: Full Scale Graduations (10,000) 
Enter the number of graduations at full scale. The full-scale graduations are calculated 
using the count-by, decimal position, and full-scale weight. 
Full Scale Graduations = Full Scale Weight / count-by. 
For example, if Full Scale Weight = 600.0 and count-by = 0.2 then Full Scale 
Graduations = 600.0 / 0.2 = 3000. 
Scale Parameter 3: Overload Graduations (10,200) 
Enter the number of graduations at which the scale is in overload status. The DT220 
displays “Error: Over Weight” when the scale weight exceeds overload. For example, if 
the Full Scale Graduations is 10,000 grads and the scale is rated for 2% overload, then 
Overload Graduations = 10,000 + (10,000 x 0.02) = 10,200. 
Scale Parameter 4.1: Count-by (1) 
Enter the primary units count-by. For example, if the scale is configured for: 
  100 kg x 0.02kg then enter 0.02 
Scale Parameter 4.2: Alternate Count-by  (0.5) 
Enter the alternate units count-by. 