Manual

DT220 Users Manual version 1.a  Configuration Parameters 
    16 
Scale Parameter 5.1: Primary Units Type (lb) 
The scale is calibrated in the primary units. The Units key is used to toggle the weight 
display between primary units and alternate units. Select the primary units from the 
displayed list. 
Scale Parameter 5.2 Alternate Units Type (kg) 
The alternate units are displayed (and printed) using the Units key to toggle between the 
primary and alternate units. Select the alternate units from the displayed list. 
Scale Parameter 5.3 Alt Units Conversion Factor  (45,360) 
The DT220 calculates the alternate weight by multiplying the primary weight by the 
conversion factor and then dividing by 100,000. The following table lists some common 
conversions. 
      Alternate Units Conversion Factor Table 
Conversion  Conversion Factor  Conv. Fact. x 100,000 
lb to kg  0.45359 kg/lb  45,359 
kg to lb  2.20462 lb/kg  220,462 
lb to ton  0.0005 Ton/lb  50 
kg to tonne  0.001 tonne/kg  100 
gram to oz  0.352739 oz/gram  352,739 
oz to gram  28.3495 gram/oz  2,834,950 
lb to lb 
kb to kg 
Etc. 
1  100,000 
Enter the conversion factor x 100,000 for the configured alternate units. 
Scale Parameter 6.1: Push Button Zero Percent (100) 
Enter the percent of full-scale capacity that can be acquired as the zero point with the 
ZERO key. 1 = 1%, 2 = 2%, ... 100 = 100%. 
Scale Parameter 6.2: Zero Tracking Delay (0) 
The automatic zero tracking function removes small deviations from zero. The DT220 
adjusts the zero setting by approximately 1/30
th
 of a display digit per delay interval. The 
delay interval is the number effective A/D conversions between adjustments. 