Manual
DT220 Users Manual version 1.a  Configuration Parameters 
    21 
1 - AND: <status>, <mode>, <polarity><weight><units><terminate> 
    Status:   OL (overload), ST (stable), US (unstable, in motion) 
    Mode:   GS (gross mode), NT (net mode) 
    Polarity:  + (positive weight), - (negative weight) 
    Weight:  7 characters data, NOT zero blanked, with decimal point 
    Units:    lb, kg, t (ton), tn (tonne), g<sp> (gram), oz 
    Terminate:  lf, cr (line feed, carriage return) 
2 - CONDEC: <stx><polarity><weight><units><mode>>status><terminate> 
    Polarity:  space (positive weight), - (negative weight) 
    Weight:  7 characters, zero blanked, with decimal point 
    Units:    L (lb), K (kg), T (ton), G (gram), O (oz) 
    Mode:   G (gross mode), N (net mode) 
    Status:  
<space> (valid weight), M (motion), O (over wt), I(invalid)  
    Terminate:  lf, cr (line feed, carriage return) 
3 - WEIGHTRONIX: <mode1><mode2><polarity><weight><space><units><term> 
    Mode1:  space (gross mode), 0 (zero if net mode) 
    Mode2:  G (gross mode), N (net mode) 
    Polarity:  + (positive weight), - (negative weight) 
    Weight:  6 characters, NOT zero blanked, with decimal point 
    Units:    lb, kg, oz, g <space>(gram), t<space> (ton), tn (tonne) 
    Terminate:  lf, cr (line feed, carriage return) 
4 - OHAS:  <polarity><weight><space><units><2 spaces><mode><status><term> 
    Polarity:  space (positive weight), - (negative weight) 
    Weight:  7 digits, zero blanked, with decimal point 
    Units:    lb, kg, oz, g <space>(gram), t<space> (ton), tn (tonne) 
    Mode:   G (gross mode), N (net mode) 
    Status:   <space> (valid weight), M (motion), O (over wt), I(invalid) 
    Terminate:  lf, cr (line feed, carriage return) 
5 - Transmits the contents of DT220 registers. 
Data entered into a text register can include other register data. Example of register 128 
(Text1) emulating a Condec format without the polarity or status in Gross mode with lbs 
units. Set TX Continuous Format setting to 128 and configure text register 128 to: 
<A2><F81>GL<A10><A13> this = stx, 7 chars of gross wt, G, L, lf, cr 
<Rreg no> =  buffer register data, minimum size (zero blanked no spaces) 
<Freg no> =  buffer data, 7 character field, zero blanked, right justified. 
<Iprint item> = Embed print item 
<Axx> = Embed ACSII code 