CB960 Programming and Installation Instructions
Overview
The CB960 is a member of the Global Solutions Family. Indyme GSF products operate in
the 800MHz ʹ 900MHz frequency spectrum. The CB960 is a 1-button, GSF Call Box
designed for use at Customer Service locations. GSF Call Boxes are designed to
communicate with a GSF Access Point. GSF products are not compatible with legacy
devices
Programming Parameters
GSF products MUST be properly programmed to establish communication. Programming
parameters MUST match your configuration. The default settings are for testing purposes
only and should not be used. Failure to properly program your call box and access point will
prevent your devices from working.
GSF Call Boxes have four primary programming parameters; Frequency Plan, Netcode, Address and
Operating Mode. These MUST be programmed in the correct order to establish communication and
ensure proper operation. Identify the parameters for your configuration before you begin
programming.
Using the programming instructions below set the following parameters in order.
x Frequency Plan ʹ defines the frequency for your GSF devices.
x Netcode ʹ unique identification code for the installation environment.
x Address ʹ alarm number associated with a control unit alarm event.
x Operating Mode ʹ defines how the call box will respond when activated.
Programming a call box requires a series of button presses. The specific buttons vary by call box
type. On the CB960, SET is the large black button and RESET is a small circle near the bottom of
the call box. The assurance LED is red and is located below the SET button. This LED will flash
during programming to indicate your progress.
Frequency Plan *FP03 USA/Australia -918.100MHz
Netcode *00000001
Address *0001
Operating Mode *1
* Default parameters are for testing purposes only.
Reset
LED