GSF Call Box Programming
GSF Call Boxes function in the 800MHz ʹ 900MHz frequency spectrum. These wireless transceivers,
communicate with the CB951 Access Point. Each call box MUST be programmed with the correct
parameters to match the CB951 Access Point(s). Call Boxes use a hierarchy based menu structure. You
must enter the Programming Menu first, to select the desired submenu. Each submenu may have one or
more options available. These options are used to assign specific operational characteristics to the call
box. Review the submenus/options before you begin programming. The submenus/options will vary by
call box model.
Enter the Programming Menu
Press and hold the RESET button until the assurance LED flashes one time.
Press and hold the SET button, until the assurance LED flashes two times.
Press and hold the RESET button, until the assurance LED flashes three times.
The call box is now in the Programming Menu mode, proceed to the desired submenu.
The call box will automatically exit any programming menu if no buttons are pressed for 30-seconds.
Menu-1: Call Box Address Programming
Assigns the call box to a corresponding alarm event programmed in the control unit. A call box address is
a four digit number from 0001 to 0999. Leading zeros are required.
After entering the Programming Menu;
Press the SET button one time for Menu-1, RESET once to save.
The assurance LED will flash one time to indicate Menu-1 was selected.
Use SET and RESET to program the 4-digit address as follows;
SET = digits 1-9, RESET = digit 0 and SAVE. Leading zeros are required
For example, program Alarm-0802 as follows:
Press RESET once to represent the zero. (0)
Press SET eight times, RESET once to save. (8)
Press RESET once to represent the zero. (0)
Press SET two times, RESET once to save. (2)
Note: When the RESET button is pressed to save the 4
th
digit, the assurance LED will flash to indicate the
address that was entered. The assurance LED will indicate digit zero by a long flash. (Approximately 1-