Safety Information

Report No.: ECT2017E07069-X1
Shenzhen ECT Testing Technology Co., Ltd. Page 7 of 8
2.3. Radiation Limit
Frequency
MHz
Distance
(Meter/s)
Field Strengths Limits
dB(V)/m
30 ~ 88 3 40.0
88 ~ 216 3 43.5
216 ~ 960 3 46.0
960 ~ 1000 3 54.0
Remark: (1) Emission level (dB (V)/m) = 20 log Emission level (V/m)
(2) The smaller limit shall apply at the cross point between two
frequency bands.
(3) Distance refers to the distance in meters between the
measuring instrument, antenna and the closed point of any part
of the device or system.
2.4. EUT Configuration on Test
The following equipments are installed on RF LINE VOLTAGE Test to meet
the Commission requirement and operating regulations in a manner that
tends to maximize its emission characteristics in a normal application.
2.4.1.C2578C(EUT)
Model No.
:
C2578C
Serial Number
:
N/A
Manufacturer
:
Dongguan City nano Electronics Co., Ltd
2.5. Operating Condition of the EUT
2.5.1. Setup the EUT and simulator as shown on Section 3.2.
2.5.2. Turn on the power of all equipment.
2.5.3. Let the EUT work in test mode (On) and measure it.