Safety Information

Report No.: ECT2017E07069-X1
Shenzhen ECT Testing Technology Co., Ltd. Page 8 of 8
2.6. Test Procedure
The EUT and its simulators are placed on a turned table that is 0.8 meter
above the ground. The turned table can rotate 360 degrees to determine the
position of the maximum emission level. The EUT is set 3 meters away from
the receiving antenna that is mounted on the antenna tower. The antenna can
move up and down between 1 meter and 4 meters to find out the maximum
emission level. Broadband antenna (calibrated biconical and log periodical
antenna) is used as receiving antenna. Both horizontal and vertical
polarization of the antenna is set on test. In order to find the maximum
emission levels, the interface cable must be manipulated according to ANSI /
IEEE Standard 187-1990 on radiated emission test.
The bandwidth setting on the field strength meter (R & S Test Receiver
ES126) is set at 120 KHz.
The frequency range from 30MHz to 1000MHz is checked. The test data are
listed in the Section 3.7 and the scanning waveform are attached within
Appendix II.
2.7. Radiated Emission Test Result
PASS.
Detailed information, please see the appendix (II) file.