Manual

Zero Point Adjustment
Zero point readjustments are automatically carried out during
operation of the gauge, no manual adjustment is needed.
Returning the Product
WARNING
WARNING: forwarding contaminated products
Contaminated products (e.g. radioactive, toxic,
caustic or microbiological hazard) can be detri-
mental to health and environment.
Products returned to INFICON should preferably
be free of harmful substances. Adhere to the for-
warding regulations of all involved countries and
forwarding companies and enclose a duly com-
pleted declaration of contamination
Products that are not clearly declared as "free of harmful
substances" are decontaminated at the expense of the
customer.
Products not accompanied by a duly completed declaration of
contamination are returned to the sender at his own expense.
Disposal
DANGER
DANGER: contaminated parts
Contaminated parts can be detrimental to health
and environment.
Before beginning to work, find out whether any
parts are contaminated. Adhere to the relevant
regulations and take the necessary precautions
when handling contaminated parts.
N
WARNING
WARNING: substances detrimental to the en-
vironment
Products or parts thereof (mechanical and elec-
tric components, operating fluids etc.) can be
detrimental to the environment.
Dispose of such substances in accordance with
the relevant local regulations.
Separating the components
After disassembling the product, separate its components
according to the following criteria:
Contaminated components
Contaminated components (radioactive, toxic, caustic, or
biological hazard etc.) must be decontaminated in accord-
ance with the relevant national regulations, separated
according to their materials, and recycled.
Other components
Such components must be separated according to their
materials and recycled.
Further Information
[1] www.inficon.com
Operating Manual
tina46d1 (German)
tina46e1 (English)
Bayard-Alpert Pirani Gauge BPG402-S, BPG402-SD,
BPG402-SL, BPG402-SP
INFICON AG, LI–9496 Balzers, Liechtenstein
[2] www.inficon.com
Instruction Sheet
tima47d1 (German)
tima47e1 (English)
Bayard-Alpert Pirani Gauge BPG402-SD, BPG402-SP
INFICON AG, LI–9496 Balzers, Liechtenstein
Declaration of Contamination
Legally binding declaration:
We hereby declare that the information on this form is
complete and accurate and that we will assume any further
costs that may arise. The contaminated product will be dis-
patched in accordance with the applicable regulations.
Organization/company
Address
Post code, place
Phone Fax
Email
Name
Company stamp
Copies: Original for addressee
1 copy for accompanying documents
1 copy for file of sender
Operating fluid(s) used
(Must be drained before shipping.)
The service, repair, and/or disposal of vacuum equipment and com-
ponents will only be carried out if a correctly completed declaration
has been submitted. Non-completion will result in delay.
This declaration may only be completed (in block letters) and signed
by authorized and qualified staff.
Reason for return
Description of product
Type
Part number
Serial number
no yes
Used in copper process
Seal product in plastic
bag and mark it with a
corresponding label.
This form can be downloaded from our website.
The product is free
of any substances
which are damaging
to health.
yes
Process related contamination of product:
toxic no 1) yes
corrosive no 1) yes
biological hazard no yes 2)
explosive no yes 2)
radioactive no yes 2)
other harmful substances no 1) yes
1) or not containing any
amount of hazardous
residues that exceed the
permissible exposure limits
2) Products thus
contaminated
will not be
accepted with-
out written
evidence of
decontami -
nation.
Precautions associated with
substance
Action if human
contact
Trade/product name
manufacturer
Chemical name
(or symbol)
Harmful substances, gases and/or
by-products
Please list all substances, gases, and by-products
which the product may have come into contact with:
EC Declaration of Conformity
We, INFICON, hereby declare that the equip-
ment mentioned below complies with the pro-
visions of the Directive relating to electromag-
netic compatibility 2004/108/EC.
Bayard-Alpert Pirani Gauge
Dual Filament Bayard-Alpert Pirani Gauge
BPG402-S
BPG402-SD
BPG402-SL
BPG402-SP
Standards
Harmonized and international/national standards and specifi-
cations:
EN 61000-6-2:2005 (EMC: generic immunity standard)
EN 61000-6-3:2001 (EMC: generic emission standard)
EN 61010-1:2001
(Safety requirements for electrical equipment for measure-
ment, control and laboratory use)
EN 61326:1997 + A1:1998 + A2:2001 + A3:2003
(EMC requirements for electrical equipment for measurement,
control and laboratory use)
Manufacturer / Signatures
INFICON AG, Alte Landstrasse 6, LI-9496 Balzers
8 March 2010 8 March 2010
Dr. Urs Wälchli
Managing Director
Claudio Christoffel
Product Manager
LI–9496 Balzers
Liechtenstein
Tel +423 / 388 3111
Fax +423 / 388 3700
reachus@inficon.com
www.inficon.com