Manual
7 - 7
IPN 074-517-P1D
Guardian Co-Deposition Controller Operating Manual
Query/Update Utility
@QU;<param1>
@UU;<param1>;<Param1>
02 Simulate Mode (0/1)
06 Front Panel Disable
Param 1 is sum of these disable values:
1 Start Buttons 32 Zero
2 Emission 1 64 Manual Power
4 Emission 2 128 File Menu
8 DataLog 256 Edit Menu
16 Chan Edit 512 Graph Setup
For example: <Param1> = 9 would disable Start Buttons and DataLog
07 Application Visible (0/1)
11 EIES Software Version (Query only)
12 EIES Computer Operating System (Query only)
13 EIES Computer Name (Query only)
14 EIES On Top (0/1, Update only)
Query Measurement
@QM;<param1>
1n Channel n Power (n=1 to 8)
2n Channel n Rate
3n Channel n Thickness
4n Channel n Deviation
5n Sensor n Emission Current (mA), n = 1 to 4
1=Sens1, 2=Sens2, 3 = Gas1, 4=Gas2
5n Sensor n Leakage Current (mA), n = 5 to 8
5=Sens1, 6=Sens2, 7 = Gas1, 8=Gas2
6n Sensor n Power (watts), n = 1 to 4
1=Sens1, 2=Sens2, 3 = Gas1, 4=Gas2
6n Sensor n Fail (0 OK, 1 Fail), n = 5 to 8
5=Sens1, 6=Sens2, 7 = Gas1, 8=Gas2
7n Sensor n Filament Current (A), n = 1 to 4
1=Sens1, 2=Sens2, 3 = Gas1, 4=Gas2
7n Sensor n Bias Voltage (V), n =5 to 8
5=Sens1, 6=Sens2, 7 = Gas1, 8=Gas2