5.1 Step 4: Software upgrade
Let's upgrade each unit to the latest stable firmware version. Go to the Maintenance section and click on the "Check
Latest Release" button. In case a new software version is available, click on the "Upgrade Firmware" to initiate the
firmware upgrade process. Before, make sure the laptop which is connected to the unit has an Internet connection,
too. Otherwise, the manualfirmware upgrade process should be performed.
Step 5: Radio parameters configuration
Let'sconfigure the minimumneededradio parameters to establish the link.
At the unit named Master at step #3 above,go to the "Basic Settings" section, then to "Link Settings" and set this
unit with:
Type: Master.
Tx Power: e.g., -5 dBm (set the minimum value in the range, as currently,we are in the lab, and we don't
need high output power anymore).
Node Name: e.g., Master (it is the same as the value set at Device Name if this was saved before).
Mode: 802.11ac (if compatibility with InfiLINK 2x2 / InfiMAN 2x2 families devices is not required).
Channel Width: e.g., 80 MHz.
Frequency: e.g., 6020 MHz.
Frame size: e.g., 5 ms.