AUX-ODU-LPU-L Mounting
AUX-ODU-LPU-Lis installed on a mast, using clamp. Attach the grounding cable (min cross-section 2.5 mm
2
) to the
case, using grounding bolt.
12 Figure - AUX-ODU-LPU-L Mounting
During AUX-ODU-LPU-L mounting it is necessary to provide a small loop of the FTP cable that should be below the
cable gland. This ensures that water is not constantly channeled towards the connector. It will also serve as a cable
compensation for the cable linear expansion as the temperature difference result.