3.7.2 AUX-ODU-SYNCCable gland Assembling
In order to ensure that the cable gland remains sealed under any environmental conditions, please, follow the
assembly sequence according to the procedure below:
Put the cable gland nut (1), the split sealing grommet (2) and the cable gland threaded coupling (3) onto the
cable
Crimp the connector onto the cable using the crimping tool:
For connection to the port Power terminate theFTPCat.5ecablewith the unshielded RJ-45
connector (4) according to the EIA/TIA-568B. Do not use the shielded RJ-45 connector on this end of
the cable as it should be attached on the IDU end (to provide grounding circuit)
For connection to the ports 0-6 use the ready-assembled specialized CAB-SYNCor CAB-SYNC-E(5)
cables
Insert the connector of the pre-terminated cable into the corresponding socket until you hear a click
Screw the cable gland threaded coupling (3) into the port and tighten it. Do not apply excessive force
Tighten the sealing grommet (2) by the cable gland nut (1). Do not apply excessive force.
CAUTION
Missing or bad grounding may leave the unit vulnerable to lightning damage.
CAUTION
Make sure that the connector is well-crimped. A loose connector can damage the device. Please