Erase the string you typed into the “Command” field and all output from the display section by clicking the «Clear»
button.
Stop a command execution during the execution phase by clicking the «Stop Execution» button.
By clicking the «Close» button, you return to the "Device Status" page.
You can choose between plain and rich text format by marking/unmarking the corresponding
checkbox.
You can execute the same command from the BS to all CPEs in the network (to the nodes that are linked to the BS)
by marking “Send to all” checkbox before clicking the «Execute» button.
You can upload the configuration file to the remote node by clicking the «Upload Config…» button and you can
reboot the remote node by clicking the «Reboot Remote Unit» button (a warning message pops up before the
reboot).
For the ease of usage of the "Remote Commands" tool, the corresponding buttons for the most usedWANFleX
OSCLI commands are available in the right side of the screen:
46 Figure - Remote commands
By clicking the «System Info» button, you fill in the commandfield with "system version,system uptimeandsystem
cpu"commands.
By clicking the «System Config» button, you fill in thecommandfield with "system uptimeandconfig
show"commands.
By clicking the «System Log» button, you fill in the commandfield with "system log show"command.
By clicking the «Routing Table» button, you fill in the commandfield with "netstat -r"command.
By clicking the «ARP Table» button, you fill in the commandfield with "arp view"command.
By clicking the «Switch Statistics» button, you fill in the commandfield with "switch statistics"command.
By clicking the «Link Status» button, you fill in the commandfield with "mint map detail"command.
By clicking the «Interface Table» button, you fill in the commandfield with "netstat-i"command.
By clicking the«Radio Scanner» button, you fill in the commandfield with "muffer rf6.0 -t5 -p mac3"command.
All commands are executed automatically after clicking one of the buttons mentioned above.
7.2.5.5 Link Restart
You can restart the wireless link (re-association, re-authentication and re-connection) by selecting the “Link
Restart” radio button and then by clicking the «OK» button in the link options.
NOTE
All WANFleX OS CLI commands can be executed from the "Remote Commands" tool.