Datasheet

TLE 6208-6 G
Data Sheet 14 2007-09-12
Overcurrent
Source shutdown threshold I
SDU
–2.0 –1.5 –1.0 A
Sink shutdown threshold
I
SDL
1.01.52.0A
Current limit
I
OCL
3.0 5.0 A sink and source
Shutdown delay time
t
dSD
10 25 50 µs sink and source
Open Circuit
Detection current I
OCD
15 30 50 mA
Delay time
t
dOC
200 350 600 µs–
Delay Time from Stand-by to Data In
Setup time t
set
––100µs–
Note: setup time is guarnteed by design
Output Delay Times; V
S
= 13.2 V; R
Load
= 25 (device not in stand-by for t > 1 ms)
Source (high-side) ON
t
dONH
–7.512µs–
Source (high-side) OFF
t
dOFFH
–36µs–
Sink (low-side) ON
t
dONL
–6.512µs–
Sink (low-side) OFF
t
dOFFL
–25µs–
Dead time H to L
t
DHL
1.5 µs t
dONL
t
dOFFH
Dead time L to H t
DLH
2.5 µs t
dONH
t
dOFFL
2.3 Electrical Characteristics (cont’d)
8V<V
S
< 40 V; 4.75 V < V
CC
< 5.25 V; INH = High; all outputs open; – 40 °C<T
j
< 150 °C;
unless otherwise specified
Parameter Symbol Limit Values Unit Test Condition
min. typ. max.