Datasheet

TLE6288R
Description
Data Sheet 10 Rev. 2.4, 2007-08-08
4 Description
4.1 General Functional Description
Channel 1 to 3
High Side Configuration with Charge Pump
On / off Current Control
Peak & Hold Current Control with fixed off time, values adjustable by SPI
Type of current control can be selected by SPI
Peak Current,Peak Time, Hold Current and Off-Time can be selected by SPI to set average and ripple current
for a given load (refer to Figure 6)
Channel 4 to 6
Configurable as either High or Low Side switch (by SPI)
On / Off operation
4.1.1 Output Stage Control: Parallel Control and SPI Control
A Boolean operation (either AND or OR) is performed on each of the parallel inputs IN 1 … 6 and respective SPI
data bits, in order to determine the states of the respective outputs. The type of Boolean operation performed is
programmed via the serial interface. Both, parallel inputs and respective SPI databits are high active.
Figure 4 Serial Input Bits 6-11 of Command “Channels on/off”
Each output is independently controlled by an output latch and a common reset line FSIN, which disables all
outputs. A logic high input ‘data bit’ turns the respective output channel ON, a logic low ‘data bit’ turns it OFF.
Table 2 Truth Table
Parallel Input SPI Bit Output OR Output AND
00OFFOFF
0 1 ON OFF
1 0 ON OFF
1 1 ON ON
OR
AND
Output
Driver
IN 1…6
Serial Input bits 6 -11 of command
Channels on / off