Datasheet

TLE 6368 / SONIC
Data Sheet 19 Rev. 2.2, 2006-12-01
Read Bit meaning
Function Type Bit Combination Default
Error indication,
explanation see below this
table
Latched D0 0: normal operation
1: fail function
0
Overtemperature warning Not latched D1 0: normal operation
1: prewarning
0
Status of Tracker Output
Q_T[1:6],only if output is
ON
Not latched D2
D3
D4
D5
D6
D7
1: settled output
voltage
0:Tracker turned
off or shorted
output. Also open
load may possibly
be indicated as 0.
1)
1
Indication of cold start/
warm start, Q_LDO1
Latched D8 0: cold start
1: warm start
0
Indication of cold start/
warm start, Q_LDO2
Latched D9 0: cold start
1: warm start
0
Indication for open or
closed window
Not latched D10 0: open window
1: closed window
0
Reset condition at output
Q_LDO1
Not latched D11 0: normal operation
1: Reset R1
0
Reset condition at output
Q_LDO2
Not latched D12 0: normal operation
1: Reset R2
0
Reset condition at output
Q_LDO3
Not latched D13 0: normal operation
1: Reset R3
0
Watchdog Error Latched D14 0: normal operation
1: WD error
0
DC/DC converter status Not latched D15 0: off
1: on
1
1)
Min. load current to avoid ’0’ signal caused by open load is 2mA.